An evaluation of insertion sites for mini-implants: a micro - CT study of human autopsy material.

Laursen Morten G, Melsen Birte, Cattaneo Paolo M

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

(1) To report the thickness of the cortical bone in insertion sites commonly used for orthodontic mini-implants, (2) to assess the impact of a change in insertion angle on primary cortical bone-to-implant contact, and (3) to evaluate the risk of maxillary sinus perforation.

MATERIALS AND

METHODS

At autopsy, 27 human samples containing three to five adjacent teeth were excised and scanned using a table-top micro-computed tomography system. Bone thickness measurements were taken at 45° and 90° to the long the axis of the adjacent teeth, simulating a mini-implant insertion at the mid-root level.

RESULTS

In the maxilla, the overall mean cortical thickness at 90° was 0.7 mm buccally in the lateral region, 1.0 mm buccally in the anterior region, and 1.3 mm palatally. In the mandible, the mean cortical thickness was 0.7 mm buccally and 1.8 mm lingually in the anterior region; 1.9 mm buccally and 2.6 mm lingually in the lateral region. Changing the insertion angle from 90° to 45° increased the cortical bone-to-implant contact by an average of 47%. Perpendicular insertion at the mid-root level only rarely interfered with the sinus, whereas apically inclined insertion increased the risk of sinus perforation.

CONCLUSIONS

Buccally and palatally in the maxilla and buccally in the anterior mandible, the thickness of the alveolar cortical bone is often less than 1 mm. In contrast, the alveolar cortical bone is frequently thicker than 2 mm laterally in the mandible. Changing the insertion angle to 45° will generally enhance implant stability but increase the risk of perforation to the maxillary sinus.

Для цитирования: Laursen Morten G, Melsen Birte, Cattaneo Paolo M. An evaluation of insertion sites for mini-implants: a micro - CT study of human autopsy material.. The Angle orthodontist. 2012. DOI: 10.2319/042512-344.1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.