MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0357020

Медицинская библиотека · PloS one · 2026

Qualitative analysis and clinical implications of lipid layer thickness variability: A retrospective, cross-sectional study.

Lee Jiyoung Emily, Kim Dong-Kyu, Yoon Hye Yeon, Whang Woong-Joo, Hwang Ho Sik, Kim Hyun-Seung, Arita Reiko, Kim Eun Chul, Na Kyung-Sun

СтатьяПеревод в очереди

Аннотация

Meibomian gland (MG) dysfunction impairs the tear film lipid layer, which is critical for preventing aqueous evaporation and maintaining tear film stability. While a LipiView® II-reported mean lipid layer thickness (LLT) of ≥100 nm indicates a high- or ceiling-range device output rather than a calibrated absolute LLT, mean LLT alone may overlook clinically relevant information about the dynamic behavior of the tear film. This study aimed to evaluate whether qualitative variability in 20-s LipiView® II dynamic LLT traces is associated with MG morphology and ocular surface findings in eyes with device-reported high-range LLT values. In this retrospective, cross-sectional study, we analyzed 20-s dynamic LipiView® II recordings from eyes that were initially measured to have a mean LLT of ≥100 nm. Two masked observers classified LLT pattern variability as high or low based on predefined criteria. Clinical and demographic differences between the high- and low-variability groups were assessed statistically. Out of 85 eyes, 58 (68.2%) and 27 (31.8%) exhibited high- and low-variability, respectively. The high-variability group demonstrated markedly elevated meiboscores compared to the low-variability group, indicating a greater degree of MG dropouts (p = 0.042). Besides elevated meiboscores, patients in the high-variability group suffered from substantially worse dry eye disease (DED) symptoms, a trend toward higher corneal and conjunctival staining scores, and significantly increased blinking frequency (p < 0.05). Qualitative evaluation of LLT revealed increased meiboscores, greater severity of DED symptoms, and increased blinking frequency even in eyes with device-reported high-range mean LLT. LLT pattern analysis may warrant evaluation as an adjunctive approach for the early detection and targeted management of MG dysfunction-related evaporative DED.

Для цитирования: Lee Jiyoung Emily, Kim Dong-Kyu, Yoon Hye Yeon, Whang Woong-Joo, Hwang Ho Sik, Kim Hyun-Seung, Arita Reiko, Kim Eun Chul, Na Kyung-Sun. Qualitative analysis and clinical implications of lipid layer thickness variability: A retrospective, cross-sectional study.. PloS one. 2026. DOI: 10.1371/journal.pone.0357020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.