MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12885-018-4113-3

Медицинская библиотека · BMC cancer · 2018

A prospective study to investigate the role of serial serum mesothelin in monitoring mesothelioma.

de Fonseka Duneesha, Arnold David T, Stadon Louise, Morley Anna, Keenan Emma, Darby Michael, Armstrong Lynne, Virgo Paul, Maskell Nick A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Radiological monitoring of malignant pleural mesothelioma (MPM) using modified RECIST criteria is limited by low sensitivity and inter-observer variability. Serial serum mesothelin measurement has shown utility in the assessment of treatment response during chemotherapy but has never been assessed in the longer term follow up of patients.

METHODS

This is a single centre study of consecutive patients diagnosed with MPM who received chemotherapy or best supportive care (BSC). Serum mesothelin measurements with paired 6 monthly CT scans were performed following the completion of chemotherapy, or from baseline in the BSC group. Changes in mesothelin were correlated with radiological progression and overall survival.

RESULTS

Forty-one patients with MPM were recruited and followed up for a minimum of 12 months (range 12-21 months). The majority of patients (n = 23) received chemotherapy with pemetrexed and cisplatin. Across the cohort a 10% rise in serum mesothelin could predict radiological progression with a sensitivity of 96% (IQR; 79-100) and specificity of 74% (IQR; 50-91). Sensitivity fell to 80% in sarcomatoid only disease. Patients with a rising mesothelin at 6 months had significantly worse overall survival (175 days) compared to stable/falling levels (448 days) (p = 0.003).

CONCLUSIONS

This is the first study to assess serum mesothelin's ability to detect progression of MPM following chemotherapy or during BSC. A 10% rise in serum mesothelin level showed excellent sensitivity at predicting progressive disease. Mesothelin measurement has several advantages over serial CT imaging including reducing hospital visits and cost.

Для цитирования: de Fonseka Duneesha, Arnold David T, Stadon Louise, Morley Anna, Keenan Emma, Darby Michael, Armstrong Lynne, Virgo Paul, Maskell Nick A. A prospective study to investigate the role of serial serum mesothelin in monitoring mesothelioma.. BMC cancer. 2018. DOI: 10.1186/s12885-018-4113-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.