MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmig.2021.07.017

Медицинская библиотека · Journal of minimally invasive gynecology · 2021

Safety and Efficacy of a Novel Barrier Film to Prevent Intrauterine Adhesion Formation after Hysteroscopic Myomectomy: The PREG1 Clinical Trial.

Weyers Steven, Capmas Perrine, Huberlant Stephanie, Dijkstra Jeroen R, Hooker Angelo B, Hamerlynck Tjalina, Debras Elodie, De Tayrac Renaud, Thurkow Andreas L, Fernandez Herve

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

OBJECTIVE

To evaluate the safety and potential efficacy of a novel degradable polymer film (DPF) designed to act as a 7-day barrier to prevent intrauterine adhesions (IUAs) after hysteroscopic myomectomy.

DESIGN

A prospective single-arm, first-in-human clinical study.

SETTING

Multicenter study involving 6 centers in France, Belgium, and the Netherlands.

PATIENTS: Women aged 40 years or older with no plans to conceive who qualified for hysteroscopic myomectomy (at least 1 10-mm type 0, 1, or 2 myoma) and had a sounded length of the uterine cavity (fundus to exocervix) ranging between 6 cm and 9 cm were considered eligible for the study.

INTERVENTIONS: The DPF was inserted after hysteroscopic transcervical myoma resection. The women were followed up by a telephone call at 30 days and second-look hysteroscopy 4 to 8 weeks after the procedure.

MEASUREMENTS AND MAIN

RESULTS

The chosen safety outcome measures were uterine perforation or cervical trauma at the time of the DPF insertion and unexpected fever, pain, or bleeding beyond 48 hours and up to 30 days after insertion, whereas the outcome measure for efficacy was the absence of IUAs on second-look hysteroscopy. A total of 23 women participated in the study. There were no incidents of uterine perforation or cervical trauma at the time of the DPF insertion. There were no reported adverse effects attributable to the DPF. On second-look hysteroscopy, 20 (87%) of the 23 women had no IUAs.

CONCLUSION

The DPF is a novel, easy-to-apply, and acceptable device to prevent IUAs, with very promising initial safety and efficacy data.

Для цитирования: Weyers Steven, Capmas Perrine, Huberlant Stephanie, Dijkstra Jeroen R, Hooker Angelo B, Hamerlynck Tjalina, Debras Elodie, De Tayrac Renaud, Thurkow Andreas L, Fernandez Herve. Safety and Efficacy of a Novel Barrier Film to Prevent Intrauterine Adhesion Formation after Hysteroscopic Myomectomy: The PREG1 Clinical Trial.. Journal of minimally invasive gynecology. 2021. DOI: 10.1016/j.jmig.2021.07.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.