m+Medelevator.RU
← Поиск публикаций
Operative neurosurgery (Hagerstown, Md.) · 2022

Interictal High Gamma Oscillation Regularity as a Marker for Presurgical Epileptogenic Zone Localization.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sato Yosuke, Tsuji Yoshihito, Yamazaki Madoka, Fujii Yoshihisa, Shirasawa Atsushi, Harada Katsuhiko, Mizutani Tohru

Аннотация

BACKGROUND: To ensure that epilepsy surgery is effective, accurate presurgical localization of the epileptogenic zone is essential. Our previous reports demonstrated that interictal high gamma oscillation (30-70 Hz) regularity (GOR) on intracranial electroencephalograms is related to epileptogenicity.

OBJECTIVE: To examine whether preoperative GOR analysis with interictal high-density electroencephalography (HD-EEG) improves the accuracy of epileptogenic focus localization and enhances postoperative seizure control.

METHODS: We calculated GOR from 20 seconds of HD-EEG data for 21 patients with refractory focal epilepsy (4 with nonlesional temporal lobe epilepsy) scheduled for epilepsy surgery. Low-resolution brain electromagnetic tomography was used to analyze the high GOR source. To validate our findings, we made comparisons with other conventional localization methods and postoperative seizure outcomes.

RESULTS: In all patients, the areas of interictal high GOR were identified and resected. All patients were seizure-free after the operation. The concordance between the results of interictal high GOR on HD-EEG and those of source estimation of interictal discharge was fully overlapping in 10 cases, partially overlapping in 8 cases, and discordant in 3 cases. The concordance between the results of interictal high GOR on HD-EEG and those of interictal 123 I-iomazenil single-photon emission computed tomography was fully overlapping in 8 cases, partially overlapping in 11 cases, and discordant in 2 cases. In 4 patients with nonlesional temporal lobe epilepsy, the interictal high GOR on HD-EEG was useful in confirming the epileptogenic zone.

CONCLUSION: The interictal high GOR on HD-EEG is an excellent marker for presurgical epileptogenic zone localization.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты