MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00590-024-03841-w

Медицинская библиотека · European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024

Fluoroscopic images of the sacroiliac joint alone are unable to identify simulated flexion or extension malreduction of the anterior pelvic ring in AO/OTA 61-B2.3 pelvic injuries.

Working Zachary M, El Naga Ashraf N, Hoogervorst Paul, Knox Riley, Marmor Meir T

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Reduction of AO/OTA 61-B2.3 (APC2) pelvic fractures is challenging in the setting of anterior ring comminution. The anterior ring is visually much simpler to evaluate for flexion or extension hemipelvis deformity than the posterior ring, except in the setting of comminution, necessitating some other visual reference to judge hemipelvis reduction. We sought to test whether pelvic inlet and outlet fluoroscopy of the contours of the sacroiliac joint could be used in isolation to judge hemipelvis flexion or extension.

METHODS

Symphyseal and anterior SIJ ligaments were cut (6 cadaveric pelvis). The symphysis was held malreduced to produce one centimeter flexion and extension deformity: 1 cm was selected to mimic a maximum clinical scenario. The SIJ was assessed using inlet and outlet fluoroscopy. The scaled width of the SIJ was assessed at the joint apertures and midjoint on both inlet and outlet views. Joint widths in flexion and extension were compared against joint widths measured on the reduced SIJ using paired t-tests.

RESULTS

There was no statistical difference in the superior (p = 0.227, 0.675), middle (p = 0.203, 0.693), and inferior (p = 0.232, 0.961) SIJ widths between hemipelvis flexion or extension models against reduced SIJ on outlet views. There was no statistical difference in the anterior (p = 0.731, 0.662), middle (p = 0.257, 0.655), and posterior (p = 0.657, 0.363) SIJ widths between flexion or extension models against reduced SIJ on inlet views.

CONCLUSION

Inspection of SIJ width on inlet and outlet fluoroscopy cannot detect up to one centimeter of hemipelvis flexion or extension malreduction in the setting of AO/OTA 61-B2.3 (APC2) pelvic fractures with complex anterior injuries.

Для цитирования: Working Zachary M, El Naga Ashraf N, Hoogervorst Paul, Knox Riley, Marmor Meir T. Fluoroscopic images of the sacroiliac joint alone are unable to identify simulated flexion or extension malreduction of the anterior pelvic ring in AO/OTA 61-B2.3 pelvic injuries.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2024. DOI: 10.1007/s00590-024-03841-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.