Ultra-low-dose computed tomography and chest X-ray in follow-up of high-grade soft tissue sarcoma-a prospective comparative study.

Salminen Samuli, Jäämaa Sari, Nevala Riikka, Sormaala Markus J, Koivikko Mika, Tukiainen Erkki, Repo Jussi, Blomqvist Carl, Sampo Mika

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Ultra-low-dose computed tomography (ULD-CT) may combine the high sensitivity of conventional computed tomography (CT) in detecting sarcoma pulmonary metastasis, with a radiation dose in the same magnitude as chest X-ray (CXR). Fifty patients with non-metastatic high-grade soft tissue sarcoma treated with curative intention were recruited. Their follow-up involved both CXR and ULD-CT to evaluate their different sensitivity. Suspected findings were confirmed by conventional CT if necessary. Patients with isolated pulmonary metastases were treated with surgery or stereotactic body radiation therapy (SBRT) with curative intent if possible. The median effective dose from a single ULD-CT study was 0.27 mSv (range 0.12 to 0.89 mSv). Nine patients were diagnosed with asymptomatic lung metastases during the follow-up. Only three of them were visible in CXR and all nine in ULD-CT. CXR had therefore only a 33% sensitivity compared to ULD-CT. Four patients were operated, and one had SBRT to all pulmonary lesions. Eight of them, however, died of the disease. Two patients developed symptomatic metastatic recurrence involving extrapulmonary sites+/-the lungs between two imaging rounds. ULD-CT has higher sensitivity for the detection of sarcoma pulmonary metastasis than CXR, with a radiation dose considerably lower than conventional CT.Clinical trial registration: NCT05813808. 04-14-2023.

Для цитирования: Salminen Samuli, Jäämaa Sari, Nevala Riikka, Sormaala Markus J, Koivikko Mika, Tukiainen Erkki, Repo Jussi, Blomqvist Carl, Sampo Mika. Ultra-low-dose computed tomography and chest X-ray in follow-up of high-grade soft tissue sarcoma-a prospective comparative study.. Scientific reports. 2024. DOI: 10.1038/s41598-024-57770-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.