OBJECTIVE

This study aimed to determine the thoracic and extra-thoracic extension of the disease in patients diagnosed with lung cancer and who had whole-body F18-fluorodeoxyglucose positron emission tomography/CT imaging and to investigate whether there is a relationship between tumor size and extrathoracic spread.

METHODS

A total of 308 patients diagnosed with lung cancer were included in this study. These 308 patients were first classified as group 1 (SPN 30 mm>longest lesion diameter ≥10 mm) and group 2 (lung mass (longest lesion diameter ≥30 mm), and then the same patients were classified as group 3 (nodular diameter of ≤20 mm) and group 4 (nodular size of >20 mm). Group 1 was compared with group 2 in terms of extrathoracic metastases. Similarly, group 3 was compared with group 4 in terms of frequency of extrathoracic metastases. F18 fluorodeoxyglucose positron emission tomography/CT examination was used to detect liver, adrenal, bone, and supraclavicular lymph node metastasis, besides extrathoracic metastasis.

RESULTS

Liver, bone, and extrathoracic metastasis in group 1 was statistically lower than in group 2 (p<0.001, p<0.01, and p=0.03, respectively). Liver, extrathoracic, adrenal, and bone metastasis in group 3 was statistically lower than that in group 4 (p<0.001, p=0.01, and p=0.04, p<0.01, respectively). The extrathoracic extension was observed in only one patient in group 3. In addition, liver, adrenal, and bone metastases were not observed in group 3 patients.

CONCLUSION

Positron emission tomography/CT may be more appropriate for cases with a nodule diameter of ≤20 mm. Performing local imaging in patients with a nodule diameter of ≤20 mm could reduce radiation exposure and save radiopharmaceuticals used in positron emission tomography/CT imaging.

Для цитирования: Tuzcu Şadiye Altun, Kaplan İhsan, İbiloğlu İbrahim, Uyar Ali, Güzel Fatih, Güzel Yunus, Taşdemir Bekir. Local imaging to interpret tumor size in F18 fluorodeoxyglucose positron emission tomography/CT in lung cancers.. Revista da Associacao Medica Brasileira (1992). 2024. DOI: 10.1590/1806-9282.20230762.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.