Cancer imaging : the official publication of the International Cancer Imaging Society · 2024
Deep learning-based metastasis detection in patients with lung cancer to enhance reproducibility and reduce workload in brain metastasis screening with MRI: a multi-center study.
Многоцентровое исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Park Yae Won, Park Ji Eun, Ahn Sung Soo, Han Kyunghwa, Kim NakYoung, Oh Joo Young, Lee Da Hyun, Won So Yeon, Shin Ilah, Kim Ho Sung, Lee Seung-Koo
Аннотация
OBJECTIVES: To assess whether a deep learning-based system (DLS) with black-blood imaging for brain metastasis (BM) improves the diagnostic workflow in a multi-center setting.
MATERIALS AND METHODS: In this retrospective study, a DLS was developed in 101 patients and validated on 264 consecutive patients (with lung cancer) having newly developed BM from two tertiary university hospitals, which performed black-blood imaging between January 2020 and April 2021. Four neuroradiologists independently evaluated BM either with segmented masks and BM counts provided (with DLS) or not provided (without DLS) on a clinical trial imaging management system (CTIMS). To assess reading reproducibility, BM count agreement between the readers and the reference standard were calculated using limits of agreement (LoA). Readers' workload was assessed with reading time, which was automatically measured on CTIMS, and were compared between with and without DLS using linear mixed models considering the imaging center.
RESULTS: In the validation cohort, the detection sensitivity and positive predictive value of the DLS were 90.2% (95% confidence interval [CI]: 88.1-92.2) and 88.2% (95% CI: 85.7-90.4), respectively. The difference between the readers and the reference counts was larger without DLS (LoA: -0.281, 95% CI: -2.888, 2.325) than with DLS (LoA: -0.163, 95% CI: -2.692, 2.367). The reading time was reduced from mean 66.9 s (interquartile range: 43.2-90.6) to 57.3 s (interquartile range: 33.6-81.0) (P <.001) in the with DLS group, regardless of the imaging center.
CONCLUSION: Deep learning-based BM detection and counting with black-blood imaging improved reproducibility and reduced reading time, on multi-center validation.
MATERIALS AND METHODS: In this retrospective study, a DLS was developed in 101 patients and validated on 264 consecutive patients (with lung cancer) having newly developed BM from two tertiary university hospitals, which performed black-blood imaging between January 2020 and April 2021. Four neuroradiologists independently evaluated BM either with segmented masks and BM counts provided (with DLS) or not provided (without DLS) on a clinical trial imaging management system (CTIMS). To assess reading reproducibility, BM count agreement between the readers and the reference standard were calculated using limits of agreement (LoA). Readers' workload was assessed with reading time, which was automatically measured on CTIMS, and were compared between with and without DLS using linear mixed models considering the imaging center.
RESULTS: In the validation cohort, the detection sensitivity and positive predictive value of the DLS were 90.2% (95% confidence interval [CI]: 88.1-92.2) and 88.2% (95% CI: 85.7-90.4), respectively. The difference between the readers and the reference counts was larger without DLS (LoA: -0.281, 95% CI: -2.888, 2.325) than with DLS (LoA: -0.163, 95% CI: -2.692, 2.367). The reading time was reduced from mean 66.9 s (interquartile range: 43.2-90.6) to 57.3 s (interquartile range: 33.6-81.0) (P <.001) in the with DLS group, regardless of the imaging center.
CONCLUSION: Deep learning-based BM detection and counting with black-blood imaging improved reproducibility and reduced reading time, on multi-center validation.