MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/asj/sjab051

Медицинская библиотека · Aesthetic surgery journal · 2021

Particulate Debris Released From Breast Implant Surfaces Is Highly Dependent on Implant Type.

Hallab Nadim James, Samelko Lauryn, Hammond Dennis

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Although breast implants (BIs) have never been safer, factors such as implant debris may influence complications such as chronic inflammation and illness such as ALCL (anaplastic large cell lymphoma). Do different types of BIs produce differential particulate debris?

OBJECTIVES

The aim of this study was to quantify, investigate, and characterize the size, amount, and material type of both loosely bound and adherent surface particles on 5 different surface types of commercial BIs.

METHODS

Surface particles from BIs of 5 surface types (n = 5/group), Biocell, Microcell, Siltex, Smooth, SmoothSilk, and Traditional-Smooth, were: (1) removed by a rinsing procedure and (2) removed with ultrapure adhesive carbon tabs. Particles were characterized (ASTM 1877-16) by scanning electron microscopy and energy-dispersive X-ray chemical analysis.

RESULTS

Particles rinsed from Biocell, Microcell and Siltex were <1 μm in diameter whereas SmoothSilk and Traditional-Smooth surfaces had median sizes >1 μm (range, 0.4-2.7 μm). The total mass of particles rinsed from the surfaces indicated Biocell had >5-fold more particulate compared with all other implants, and >30-fold more than SmoothSilk or Traditional-Smooth implants (>100-fold more for post-rinse adhesion analysis). Energy-dispersive X-ray analysis indicated that the particulate material for Biocell, Microcell, and Siltex was silicone (>50%), whereas particulates from SmoothSilk and Traditional-Smooth implants were predominantly carbon-based polymers, eg, polycarbonate-urethane, consistent with packaging (and were detected on all implant types). Generally, SmoothSilk and Traditional-Smooth implant groups released >10-fold fewer particles than Biocell, Microcell, and Siltex surfaces. Pilot ex vivo tissue analysis supported these findings.

CONCLUSIONS

Particulate debris released from BIs are highly dependent on the type of implant surface and are a likely key determinant of in vivo performance.

Для цитирования: Hallab Nadim James, Samelko Lauryn, Hammond Dennis. Particulate Debris Released From Breast Implant Surfaces Is Highly Dependent on Implant Type.. Aesthetic surgery journal. 2021. DOI: 10.1093/asj/sjab051.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.