m+Medelevator.RU
← Поиск публикаций
Artificial organs · 2019

An in vivo image acquisition system for the evaluation of tracheal mechanics in rats.

Оценочное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Valenga Marcelo Henrique, Vitorasso Renato de Lima, Rodrigues Thiago Guimarães, Pazetti Rogério, Cardoso Paulo Francisco Guerreiro, Moriya Henrique Takachi, Aoki Fabio Gava

Аннотация

Mechanical evaluation of tracheal grafts is of great relevance for transplant research. Although there are some publications demonstrating different techniques of tracheal mechanical evaluation, there is still no definitive or preferred protocol available. Here, we present a simple image processing acquisition system that can be used for in vivo experiments. Six male Wistar rats were submitted to orotracheal intubation and a longitudinal incision was made to expose the trachea. Images of tracheae were acquired from a video camera in different scenarios of bronchoconstriction using methacholine (MCh) (Basal, PBS, MCh 30 μg/kg, MCh 300 μg/kg, and postmetabolized) during imposed-inspiration and imposed-expiration. The area variation ratio (the ratio between areas during expiration vs. inspiration) was 1.1× for the Basal group, while the ratio for MCh 300 µg/kg was 6.5×. The area variation of imaged tracheae was statistically significant at the dose of MCh 300 µg/kg for imposed-inspiration versus imposed-expiration (P = .002). Likewise, elastance data of respiratory mechanics indicated a statistically significant difference at the dose of MCh 300 µg/kg for imposed-inspiration versus imposed-expiration (P = .026). Our image processing analysis protocol presented corresponding behavior when compared to mechanical parameters of the respiratory system. In addition, our image acquisition system was able to highlight the differences between imposed-inspiration and imposed-expiration. Image analysis of the tracheal area variation seems to be in agreement with the elastance of the respiratory system. Taken together, these observations may help future studies of tracheal transplantation for in situ assessment of graft patency.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты