Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2019
Is Fetal Intelligent Navigation Echocardiography Helpful in Screening for d-Transposition of the Great Arteries?
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Huang Chao, Zhao Bo Wen, Chen Ran, Pang Hai Su, Pan Mei, Peng Xiao Hui, Wang Bei
Аннотация
OBJECTIVES: To evaluate the performance of fetal intelligent navigation echocardiography (FINE) applied to spatiotemporal image correlation (STIC) volumes in generating 3 specific abnormal cardiac views (left ventricular outflow tract, right ventricular outflow tract, and 3-vessel and trachea) used to screen for d-transposition of the great arteries (d-TGA).
METHODS: In this prospective study, 1 or more STIC volumes were obtained from the 4-chamber view in 34 second- and third-trimester fetuses with d-TGA. Each appropriate STIC volume was evaluated by STICLoop (Samsung Medison, Seoul, Korea) before applying the FINE method. One optimal volume per fetus was selected by observers. The visualization rates of the 3 specific abnormal cardiac views of d-TGA and their diagnostic elements were calculated, and the reliability between 2 observers was verified by the intraclass correlation coefficient.
RESULTS: Fetal intelligent navigation echocardiography applied to STIC volume data sets of fetuses with d-TGA successfully generated the 3 specific abnormal cardiac views in the following manner for 2 observers: 75.0% (n = 21) for the left ventricular outflow tract, 89.2% (n = 25) for the right ventricular outflow tract, and 85.7% (n = 24) for the 3-vessel and trachea view. Twenty-four (85.7%) of the STIC volume data sets showed 2 or 3 of the abnormal cardiac views. The interobserver intraclass correlation coefficients between the 2 observers ranged from 0.842 to 1.000 (95% confidence interval), indicating almost perfect reliability for the 2 observers.
CONCLUSIONS: In cases of d-TGA, the FINE method has a high success rate in generating 3 specific abnormal cardiac views and therefore can be performed to screen for this congenital defect.
METHODS: In this prospective study, 1 or more STIC volumes were obtained from the 4-chamber view in 34 second- and third-trimester fetuses with d-TGA. Each appropriate STIC volume was evaluated by STICLoop (Samsung Medison, Seoul, Korea) before applying the FINE method. One optimal volume per fetus was selected by observers. The visualization rates of the 3 specific abnormal cardiac views of d-TGA and their diagnostic elements were calculated, and the reliability between 2 observers was verified by the intraclass correlation coefficient.
RESULTS: Fetal intelligent navigation echocardiography applied to STIC volume data sets of fetuses with d-TGA successfully generated the 3 specific abnormal cardiac views in the following manner for 2 observers: 75.0% (n = 21) for the left ventricular outflow tract, 89.2% (n = 25) for the right ventricular outflow tract, and 85.7% (n = 24) for the 3-vessel and trachea view. Twenty-four (85.7%) of the STIC volume data sets showed 2 or 3 of the abnormal cardiac views. The interobserver intraclass correlation coefficients between the 2 observers ranged from 0.842 to 1.000 (95% confidence interval), indicating almost perfect reliability for the 2 observers.
CONCLUSIONS: In cases of d-TGA, the FINE method has a high success rate in generating 3 specific abnormal cardiac views and therefore can be performed to screen for this congenital defect.