Single-Phase Surrogate for True Non-Contrast Liver CT Using 190-keV Monoenergetic Imaging on Photon-Counting CT: Implications for Hepatic Steatosis Assessment.

Ohtani Takashi, Shimada Masato, Nishiyama Kaede, Shimoyama Hiroki, Ueda Midori, Hakoda Sayuri, Tomita Yukihiro, Takata Kenji, Tateishi Toshiki, Tsujikawa Tetsuya

СтатьяПеревод пока не подготовлен

Аннотация

RATIONALE AND

OBJECTIVES

To evaluate whether 190-keV virtual monoenergetic imaging (VMI) using photon-counting detector CT (PCD-CT) can serve as a surrogate for true non-contrast (TNC) in hepatic steatosis quantification and to compare its attenuation agreement with virtual non-contrast (VNC).

METHODS

Forty-nine patients who underwent abdominal PCD-CT and MRI-proton density fat fraction (PDFF) within 2 months were retrospectively analyzed. VNC and 190-keV VMI were reconstructed from equilibrium-phase scans. Liver attenuation was measured on TNC, VNC, and 190-keV VMI in four hepatic segments. Pearson correlation and Bland-Altman analyses assessed agreement with TNC. Receiver operating characteristic analysis evaluated diagnostic performance for steatosis (MRI-PDFF ≥ 5%). Statistical analyses were performed using MedCalc (version 23.4) and GraphPad Prism (version 10.6.1). Statistical significance was defined as p < 0.05.

RESULTS

The study included 49 patients (30 men, 19 women; mean age, 66.7 ± 11.2 years). In whole-liver analysis, 190-keV VMI correlated strongly with TNC (r=0.921, p<0.001), comparable to VNC (r=0.925). In the anterior segment, VNC showed a larger positive bias relative to TNC (+5.5 HU), whereas 190-keV VMI showed a smaller bias (+2.2 HU) that more accurately reproduced the regional attenuation pattern. For detecting steatosis in the anterior segment, a significant difference in area under the curve was observed between TNC and VNC (0.921 vs 0.817, p=0.018), whereas no significant difference was found between TNC and 190-keV VMI (0.921 vs 0.869, p=0.149).

CONCLUSION

190-keV VMI may serve as a practical surrogate for TNC in hepatic steatosis quantification, demonstrating reduced segment-dependent bias compared with VNC in artifact-prone regions.

Для цитирования: Ohtani Takashi, Shimada Masato, Nishiyama Kaede, Shimoyama Hiroki, Ueda Midori, Hakoda Sayuri, Tomita Yukihiro, Takata Kenji, Tateishi Toshiki, Tsujikawa Tetsuya. Single-Phase Surrogate for True Non-Contrast Liver CT Using 190-keV Monoenergetic Imaging on Photon-Counting CT: Implications for Hepatic Steatosis Assessment.. Academic radiology. 2026. DOI: 10.1016/j.acra.2026.06.064.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.