The British journal of radiology · 2012
Parotid gland volumetric changes during intensity-modulated radiotherapy in head and neck cancer.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Fiorentino A, Caivano R, Metallo V, Chiumento C, Cozzolino M, Califano G, Clemente S, Pedicini P, Fusco V
Аннотация
OBJECTIVE: To evaluate volumetric changes of parotid glands (PGs) during intensity-modulated radiotherapy (IMRT) in head and neck cancer patients.
METHODS: During IMRT all patients underwent kilovolt cone-beam CT (CBCT) scans to verify the set-up positioning in a protocol study. On each CBCT scan, the PGs were retrospectively contoured and evaluated with a dose-volume histogram.
RESULTS: From February to June 2011, 10 patients were enrolled. 140 CBCT scans were registered (280 PGs): for each patient, a median of 14 CBCT scans were performed (range 14-16). At the start of radiation, the average volume for ipsilateral PGs (iPGs) was 18.77 ml (range 12.9-31.2 ml), whereas for contralateral PGs (cPGs) it was 16.63 ml (range 8.3-28.7 ml). At the last CBCT scan, the average volume loss was 43.5% and 44.0% for the iPG and cPG, respectively. When we analysed the percentage of volume loss, we observed that the volume decreased by linear regression (r(2)=0.92 for iPG; r(2)=0.91 for cPG), with an average volume loss rate of 1.5% per day for both PGs. During the third week of treatment the volume of both PGs reduced by 24-30%.
CONCLUSION: Our data show that, during IMRT, the shrinkage of PGs should be taken into account. A replan could be indicated in the third week of radiotherapy.
METHODS: During IMRT all patients underwent kilovolt cone-beam CT (CBCT) scans to verify the set-up positioning in a protocol study. On each CBCT scan, the PGs were retrospectively contoured and evaluated with a dose-volume histogram.
RESULTS: From February to June 2011, 10 patients were enrolled. 140 CBCT scans were registered (280 PGs): for each patient, a median of 14 CBCT scans were performed (range 14-16). At the start of radiation, the average volume for ipsilateral PGs (iPGs) was 18.77 ml (range 12.9-31.2 ml), whereas for contralateral PGs (cPGs) it was 16.63 ml (range 8.3-28.7 ml). At the last CBCT scan, the average volume loss was 43.5% and 44.0% for the iPG and cPG, respectively. When we analysed the percentage of volume loss, we observed that the volume decreased by linear regression (r(2)=0.92 for iPG; r(2)=0.91 for cPG), with an average volume loss rate of 1.5% per day for both PGs. During the third week of treatment the volume of both PGs reduced by 24-30%.
CONCLUSION: Our data show that, during IMRT, the shrinkage of PGs should be taken into account. A replan could be indicated in the third week of radiotherapy.