MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/08164622.2023.2258126

Медицинская библиотека · Clinical & experimental optometry · 2023

The association between ocular biometric components and corneal aberrations.

Hashemi Hassan, Mesbahi Shima, Jamali Alireza, Ostadimoghaddam Hadi, Yekta Abbasali, Khabazkhoob Mehdi

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

CLINICAL RELEVANCE: Evaluating factors affecting corneal higher-order aberration component has a very important role in interpreting the characteristics of the formed image on the retina.

BACKGROUND

To determine the relationship between ocular biometric components and corneal higher-order aberrations in an elderly population.

METHODS

This report is related to a subsample of the Tehran Geriatric Eye study (TGES), a population-based cross-sectional study that was conducted on individuals aged 60 years and above in Tehran city, Iran using multistage stratified random cluster sampling. All study participants underwent ocular examinations including visual acuity measurement, refraction and slit-lamp biomicroscopy. Anterior segment imaging and corneal aberrometry were performed using Pentacam AXL.

RESULTS

In the present study, 644 eyes of 415 individuals (56.9% female) with mean age of 66.36 ± 4.70 years were evaluated. According to a multiple generalised estimating equation model, the root mean square of total higher-order aberrations was related to age (β = 0.081, p = 0.002), crystalline lens thickness (β = 0.08, p < 0.001), and corneal diameter (β = -0.04, p = 0.014). The root mean square of total coma aberration was directly related to the female sex (β = 0.02, p = 0.05), and crystalline lens thickness (β = 0.06, p < 0.001). There was a direct relationship between the root mean square of third- and fourth-order higher-order aberrations and crystalline lens thickness (p < 0.001). Spherical aberration was directly related to the male sex (β = -0.02, p = 0.004), axial length (β = 0.05, p < 0.001) and central corneal thickness (β = 0.001, p = 0.025), and was inversely related to anterior chamber depth (β = -0.07, p = 0.031) and crystalline lens thickness (β = -0.25, p < 0.001).

CONCLUSION

Ocular biometric components are related to corneal aberrations in the elderly. These factors need to be considered in respect of medical and surgical procedures required for the elderly.

Для цитирования: Hashemi Hassan, Mesbahi Shima, Jamali Alireza, Ostadimoghaddam Hadi, Yekta Abbasali, Khabazkhoob Mehdi. The association between ocular biometric components and corneal aberrations.. Clinical & experimental optometry. 2023. DOI: 10.1080/08164622.2023.2258126.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.