m+Medelevator.RU
← Поиск публикаций
The Laryngoscope · 2014

Contrast-enhanced ultrasound-guided Sentinel lymph node biopsy of the ocular conjunctiva.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rabinowitz Mindy R, Merton Daniel A, Liu Ji-Bin, Saxena Shivam, Pluta John, Eisenbrey John R, Baker Adam L, Rabinowitz Michael P, Lally Sara, Cognetti David, Goldberg Barry B, Pribitkin Edmund A, Curry Joseph M

Аннотация

OBJECTIVES/HYPOTHESIS: Sentinel lymph node biopsy (SLNB) has been utilized for cutaneous melanoma and other malignancies arising from the eye and ocular adnexa. Currently, SLNB requires blue dyes and/or radiopharmaceuticals; both of which have significant shortcomings. This study sought to evaluate the feasibility of SLNB with the use of real-time, contrast-enhanced ultrasound (CEUS) as an alternative technique for tumors arising in the conjunctiva.

STUDY DESIGN: Prospective feasibility study in a porcine model.

METHODS: Twelve experiments were performed on six non-tumor-bearing Yorkshire swine. An ultrasound contrast agent, Sonazoid (GE Healthcare, Oslo, Norway), (99m) technetium ((99m) Tc), and methylene blue (MB) (Covidien, Mansfield, MA) were injected in the ocular conjunctiva. Sentinel lymph nodes (SLNs) were localized with CEUS and findings were compared to that of MB and (99m) Tc. Fisher exact test was used.

RESULTS: Contrast-enhanced SLNs were identified within an average of 6.2 minutes from time of injection of Sonazoid. A total of 17 SLNs were identified by at least one of the three techniques. Correlation between Sonazoid and (99m) Tc was 94.1% (16/17 SLNs). Correlation between (99m) Tc and MB was 88.2% (15/17). One SLN that was positive for (99m) Tc but negative for Sonazoid and was considered to be a false positive (1/17); findings were similar for MB (1/17). Differences between the three techniques were not significant (P = .886).

CONCLUSIONS: CEUS-guided injection of conjunctiva for SLNB is technically feasible and correlates well with standard detection techniques. This technique shows promise for rapid, real-time, intraoperative imaging for SLNB, using a widely available imaging modality and avoiding the need for radiopharmaceuticals.

LEVEL OF EVIDENCE: NA

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты