MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.jvca.2024.09.140

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2024

Correlation Between Intraoperative Near-infrared Spectroscopy Values and Neurologic Outcomes in Patients Undergoing Total Aortic Arch Replacement Using the Frozen Elephant Trunk Technique.

Kletzer Joseph, Czerny Martin, Kreibich Maximilian, Berger Tim, Bauer Nils, Dimov Aleksandar, Fagu Albi, Eschenhagen Matthias, Lehane Cornelius, Kondov Stoyan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To correlate intraoperative near-infrared spectroscopy (NIRS) values with neurologic outcomes in patients undergoing total aortic arch replacement using the frozen elephant trunk (FET) technique.

DESIGN

Retrospective, single-center registry study using a two-way repeated-measures analysis of variance.

SETTING

Between November 2013 and December 2023, 427 patients were treated for acute and chronic aortic pathologies using the FET procedure.

PARTICIPANTS

A total of 166 patients with complete NIRS data at all predefined time points were included and retrospectively divided into two groups: patients diagnosed by experienced radiologists and clinicians with stroke and without stroke after FET.

MEASUREMENTS: Bilateral NIRS values were recorded continuously and at seven critical time points in each patient, and correlations were made between left- and right-sided NIRS values and stroke.

MAIN

RESULTS

A total of 23 patients (13.9%) were diagnosed with stroke. There was a significantly higher in-hospital mortality in patients with stroke (21.7%) compared with patients without stroke (7.7%, p = 0.037). Left-sided regional cerebral oxygenation did not show significant difference in patients with versus without stroke (p = 0.550). Differences were detected in right-sided regional cerebral oxygenation trends (p < 0.001) and interhemisphere NIRS at specified time points (p = 0.009). The interaction, time × stroke, however, did not show significant results in any analysis (p > 0.05).

CONCLUSION

NIRS is a reliable tool to monitor intraoperative frontal lobe cerebral oxygen saturation. However, its use to predict postoperative stroke remains limited. Further refinements are needed to develop the technique into a prediction tool.

Для цитирования: Kletzer Joseph, Czerny Martin, Kreibich Maximilian, Berger Tim, Bauer Nils, Dimov Aleksandar, Fagu Albi, Eschenhagen Matthias, Lehane Cornelius, Kondov Stoyan. Correlation Between Intraoperative Near-infrared Spectroscopy Values and Neurologic Outcomes in Patients Undergoing Total Aortic Arch Replacement Using the Frozen Elephant Trunk Technique.. Journal of cardiothoracic and vascular anesthesia. 2024. DOI: 10.1053/j.jvca.2024.09.140.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.