An optimized abnormal muscle response recording method for intraoperative monitoring of hemifacial spasm and its long-term prognostic value.

Huang Chuyi, Miao Suhua, Chu Heling, Dai Chuanfu, Wu Jinting, Wang Junhua, Zuo Huancong, Ma Yu

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Intraoperative electrophysiological monitoring is used to determine whether decompression is sufficient during microvascular decompression (MVD) for hemifacial spasm (HFS). However, the real offending vessel is sometimes neglected by the neurosurgeons. Here, we reported our experience in using optimized abnormal muscle response (AMR) monitoring and continuous intraoperative monitoring for MVD.

METHODS

This study included 2161 HFS patients who underwent MVD using traditional (1023 patients) and optimized (1138 patients) methods. Modified AMR monitoring was adopted in our study, with the zygomatic branch of the facial nerve stimulated and the temporal branch, buccal branch, marginal mandibular branch and cervical branch of the facial nerve detected for AMR. These cases were analyzed retrospectively with emphasis on the postoperative outcomes and intraoperative findings. The therapeutic effect was evaluated at day 1, month 3 and year 1 after operation.

RESULTS

The relief rate at day 1, month 3 and year 1 after operation for patients who employed optimized AMR recording method was 95.1%, 97.4% and 99.3%, comparing with 92.2%, 95.0% and 97.8% in traditional method. There was significant difference in achieved immediate remission and recovery rate during 12-month follow-up between the two groups (P < 0.05). The modified intraoperative monitoring showed the sensitivity of AMR disappearance to judge the relief at day 1, month 3 and year 1 after HFS operation was 95.7%, 96.3% and 97.3%, respectively; the specificity was 44.6%, 43.3% and 50.0%, respectively; the accuracy was 93.1%, 94.9% and 97.4%, respectively.

CONCLUSIONS

Our findings demonstrated that the optimized method could improve the positive detection rate of AMR and accuracy of decompression effect prediction. The evaluation for the decompression effect by optimized intraoperative monitoring can increase the immediate remission rate and reduce the delayed recovery rate.

Для цитирования: Huang Chuyi, Miao Suhua, Chu Heling, Dai Chuanfu, Wu Jinting, Wang Junhua, Zuo Huancong, Ma Yu. An optimized abnormal muscle response recording method for intraoperative monitoring of hemifacial spasm and its long-term prognostic value.. International journal of surgery (London, England). 2016. DOI: 10.1016/j.ijsu.2016.12.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.