MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ans.14126

Медицинская библиотека · ANZ journal of surgery · 2017

Semi-Automatic Electronic Stent Register: a novel approach to preventing ureteric stents lost to follow up.

Macneil James W H, Michail Peter, Patel Manish I, Ashbourne Julie, Bariol Simon V, Ende David A, Hossack Tania A, Lau Howard, Wang Audrey C, Brooks Andrew J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Ureteric stents are indispensable tools in modern urology; however, the risk of them not being followed-up once inserted poses medical and medico-legal risks. Stent registers are a common solution to mitigate this risk; however, manual registers are logistically challenging, especially for busy units.

METHODS

Western Sydney Local Health District developed a novel Semi-Automatic Electronic Stent Register (SAESR) utilizing billing information to track stent insertions. To determine the utility of this system, an audit was conducted comparing the 6 months before the introduction of the register to the first 6 months of the register.

RESULTS

In the first 6 months of the register, 457 stents were inserted. At the time of writing, two of these are severely delayed for removal, representing a rate of 0.4%. In the 6 months immediately preceding the introduction of the register, 497 stents were inserted, and six were either missed completely or severely delayed in their removal, representing a rate of 1.2%. A non-inferiority analysis found this to be no worse than the results achieved before the introduction of the register.

CONCLUSION

The SAESR allowed us to improve upon our better than expected rate of stents lost to follow up or severely delayed. We demonstrated non-inferiority in the rate of lost or severely delayed stents, and a number of other advantages including savings in personnel costs. The semi-automatic register represents an effective way of reducing the risk associated with a common urological procedure. We believe that this methodology could be implemented elsewhere.

Для цитирования: Macneil James W H, Michail Peter, Patel Manish I, Ashbourne Julie, Bariol Simon V, Ende David A, Hossack Tania A, Lau Howard, Wang Audrey C, Brooks Andrew J. Semi-Automatic Electronic Stent Register: a novel approach to preventing ureteric stents lost to follow up.. ANZ journal of surgery. 2017. DOI: 10.1111/ans.14126.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.