MedElevator Войти в исследования
← Поиск публикаций

DOI 10.64898/2026.06.30.735710

Медицинская библиотека · bioRxiv : the preprint server for biology · 2026

APRIL: Adaptive Regression-Based Two-Dimensional Quantitative Anisotropy Imaging Using Acoustic Radiation Force Impulse.

Hassan Walid, Crook Kayla, Gi Young Jin, Lee Jangsoon, Hossain Murad

СтатьяПрепринтПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study aims to develop and validate a quantitative, depth-resolved anisotropy imaging framework that extends ARFI-based focal degree-of-anisotropy (DoA) estimation into two-dimensional mapping by modeling the depth-dependent relationship between shear modulus ratio (SMR) and peak displacement ratio (PDR).

METHODS

We propose APRIL (Adaptive Polynomial Regression for anisotropy Imaging via ARFI-induced DispLacements), a framework for quantitative, depth-resolved DoA imaging that adaptively selects polynomial regression or shape-preserving spline interpolation based on excitation PSF asymmetry. Training data were generated using an LS-DYNA3D + Field II simulation pipeline in homogeneous transversely isotropic media (SMR 0.9-4.9). Testing included shifted SMRs under varied acoustic conditions and three heterogeneous inclusion configurations (anisotropic inclusion in isotropic background and vice versa). Experimental validation was performed in an in-vivo murine tumor model over the time, ex-vivo chicken breast, and tissue-mimicking gelatin phantoms, using a Verasonics system with an L11-5v transducer.

RESULTS

APRIL achieved depth-resolved SMR prediction errors below 9% over 10-30 mm, with highest accuracy in the focal region (MAE 2.3%, RMSE < 0.1) and stable performance across PSF transition zones. In heterogeneous phantoms, it reconstructed anisotropy maps with SSIM up to 86% and MPE below 7%, accurately delineating inclusion boundaries. Under acoustic parameter variations, mean absolute errors remained below 10%, demonstrating robustness to system and tissue heterogeneity.

CONCLUSION

APRIL enables robust, two-dimensional anisotropy imaging beyond focal estimates.

SIGNIFICANCE: The method provides a physically grounded and generalizable framework for clinically viable anisotropy biomarkers in muscle, tendon, kidney, tumor and breast tissues.

Для цитирования: Hassan Walid, Crook Kayla, Gi Young Jin, Lee Jangsoon, Hossain Murad. APRIL: Adaptive Regression-Based Two-Dimensional Quantitative Anisotropy Imaging Using Acoustic Radiation Force Impulse.. bioRxiv : the preprint server for biology. 2026. DOI: 10.64898/2026.06.30.735710.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.