MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.iccn.2026.104531

Медицинская библиотека · Intensive & critical care nursing · 2026

Negative inspiratory force predicts extubation failure after planned extubation in a medical ICU: a prospective cohort study.

Choe Junsu, Nam Jimyoung, Lee Hee Og, Cho Soo-Hyun, Jung Jinhee, Won Sun Young, Jeon Kyeongman

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

Although negative inspiratory force (NIF) has been studied in relation to weaning failure, evidence addressing extubation failure after a successful spontaneous breathing trial (SBT) remains limited. In standardized, protocol-based weaning programs, ventilator-measured NIF may offer information for extubation decisions, but prospective data are scarce.

METHODS

We performed a prospective observational cohort study in medical ICUs using a respiratory care practitioner-driven, standardized weaning program. Adult patients receiving invasive mechanical ventilation for ≥2 calendar days were enrolled between November 2017 and February 2022. Planned extubation episodes after a successful SBT were analyzed. NIF was measured at the bedside by respiratory care practitioners using the ventilator's built-in function and categorized a priori. The primary outcome was extubation failure, defined as reintubation within 48 h after extubation.

RESULTS

Among 622 planned extubation episodes, extubation failure occurred in 97 (15.6%). Extubation failure rates decreased stepwise across increasing NIF categories (35.7% for NIF <15 cmH₂O vs. 11.2% for NIF ≥25 cmH₂O; P for trend <0.001). In the fully adjusted model, compared with NIF <15 cmH₂O, NIF 20-24 cmH₂O and ≥25 cmH₂O were independently associated with lower odds of extubation failure (adjusted odds ratios of 0.29 and 0.25, respectively). Hypercapnic or hypoxemic respiratory failure, deep sedation, thick secretions, higher non-neurologic Sequential Organ Failure Assessment score, and delirium were also independently associated with extubation failure. Extubation failure was associated with a higher rate of tracheostomy before ICU discharge (66.0% vs. 5.0%) and higher ICU mortality (10.3% vs. 3.2%).

CONCLUSIONS

In medical ICU patients undergoing planned extubation after a successful SBT, higher NIF was independently associated with lower odds of extubation failure.

IMPLICATIONS FOR CLINICAL PRACTICE: These findings support the use of ventilator-measured NIF as a practical adjunct to the multifactorial extubation assessment within standardized weaning programs.

Для цитирования: Choe Junsu, Nam Jimyoung, Lee Hee Og, Cho Soo-Hyun, Jung Jinhee, Won Sun Young, Jeon Kyeongman. Negative inspiratory force predicts extubation failure after planned extubation in a medical ICU: a prospective cohort study.. Intensive & critical care nursing. 2026. DOI: 10.1016/j.iccn.2026.104531.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.