MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2025.111956

Медицинская библиотека · European journal of radiology · 2025

The impact of the novel CovBat harmonization method on enhancing radiomics feature stability and machine learning model performance: A multi-center, multi-device study.

Zhou Chuanghui, Zhou Jianwei, Lv Yijun, Batuer Maidina, Huang Jinghan, Zhong Junyuan, Zhong Haijian, Qin Genggeng

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: This study aims to assess whether the novel CovBat harmonization method can further reduce radiomics feature variability from different imaging devices in multi-center studies and improve machine learning model performance compared to the ComBat method.

MATERIALS: Non-contrast abdominal CT scans of 1,000 healthy subjects from three medical institutions (from four manufacturers and eight different models) were retrospectively included: Hospital A (n = 513), Hospital B (n = 338), and Hospital C (n = 149). 93 radiomics features were extracted from liver and spleen tissues using PyRadiomics. Performing a binary classification task of liver and spleen tissues on the pooled data from the three institutions: (1) Unharmonized, (2) ComBat, and (3) CovBat. Models were built separately for each radiomics feature classes (First-order, GLCM, GLRLM, GLSZM, NGTD, GLDM), as well as a combined model integrating all feature classes. The Kruskal-Wallis test and principal component analysis (PCA) were used to assess the variability of radiomics features among the groups. Multiple linear regression models were used to analyze the sources of variation. Accuracy, sensitivity, specificity, F1-score, and area under the curve (AUC) were used to evaluate model performance.

RESULTS

After ComBat and CovBat harmonization, the number of consistent features increased by 68.82 % and 73.12 %, respectively, and the feature variability due to hardware differences decreased from 12.32-25.38 % to 1.89-2.01 % with ComBat and 1.19-1.88 % with CovBat. The AUC of the machine learning models improved significantly: Combined (Unharmonized: 0.93, ComBat: 0.99, CovBat: 1.00), First-order (0.93, 0.98, 0.98), GLCM (0.81, 0.93, 0.98), GLRLM (0.78, 0.96, 0.98), NGTDM (0.75, 0.96, 0.98), GLSZM (0.78, 0.93, 0.97), and GLDM (0.83, 0.94, 0.97). DeLong's test showed that the results before and after harmonization were statistically significant (P < 0.05).

CONCLUSION

CovBat further reduced radiomics feature variability caused by different CT scanners and significantly improved the performance of machine learning models, although the degree of improvement varied across different feature categories.

Для цитирования: Zhou Chuanghui, Zhou Jianwei, Lv Yijun, Batuer Maidina, Huang Jinghan, Zhong Junyuan, Zhong Haijian, Qin Genggeng. The impact of the novel CovBat harmonization method on enhancing radiomics feature stability and machine learning model performance: A multi-center, multi-device study.. European journal of radiology. 2025. DOI: 10.1016/j.ejrad.2025.111956.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.