MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4187/respcare.03875

Медицинская библиотека · Respiratory care · 2015

Comparison of the Feasibility and Safety of Nasotracheal Suctioning With Curved Edge Catheter Versus Conventional Suction Catheter in Critically Ill Subjects: A Prospective Randomized Crossover Trial.

Grigoriadis Konstantinos Ε, Angouras Dimitrios C, Flevari Aikaterini, Xathos Theodoros

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Nasotracheal suctioning (NTS) is accomplished by inserting a suction catheter into the trachea through the nasopharynx. It is a useful procedure in critically ill patients whose ability to cough and mobilize secretions is impaired. Ιt was assumed that using a suction catheter with an angular tip would facilitate entry into the trachea. The primary outcome was the success rate and the ease of insertion by using a curved edge catheter (Tiemann type) compared with a conventional suction catheter. The secondary outcome was the monitoring of subject's vital signs during the intervention.

METHODS

Non-intubated subjects hospitalized in 2 adult ICUs underwent 2 consecutive NTSs each, using either a 14 French curved edge catheter or a 14 French conventional suction catheter, randomly.

RESULTS

Twenty subjects with a mean age of 75.5 y were enrolled for a time period of 5 months. The tracheal access success rate was 19/52 (successful/unsuccessful attempts) using a curved edge catheter (36.5%, 95% CI 23.6-51.0%) compared with 12/130 (9.2%, 95% CI 4.8-15.5%) using a conventional suction catheter. The insertion was 5.6 times more likely to be achieved by using a curved edge catheter (odds ratio 5.66, 95% CI 2.49-12.84, P < .001). The number of attempts required to succeed in the insertion was significantly lower when using a curved edge catheter than when using a conventional suction catheter (for nasopharynx, median [range] of 1 [1] versus 2.5 [8], P = .001; for trachea, median [range] of 2 [9] versus 9 [9], P = .002). The time required for successful insertion into the nasopharynx and trachea was significantly shorter when using a curved edge catheter than when using a conventional suction catheter (for nasopharynx, median [range] of 3 [11] s versus 5.3 [18] s, P = .038; for trachea, median [range] of 6 [27] s versus 20 [25] s, P = .002). The traumatic rate (percentage of catheters with blood present on the tip) was exactly the same for both catheters (30%).

CONCLUSIONS

It is more likely that tracheal access will be achieved using a curved edge catheter. A shorter process time and fewer attempts are required for successful NTS using a curved edge catheter, and it seems to be an equally safe procedure. (ClinicalTrials.gov registration NCT02261428.).

Для цитирования: Grigoriadis Konstantinos Ε, Angouras Dimitrios C, Flevari Aikaterini, Xathos Theodoros. Comparison of the Feasibility and Safety of Nasotracheal Suctioning With Curved Edge Catheter Versus Conventional Suction Catheter in Critically Ill Subjects: A Prospective Randomized Crossover Trial.. Respiratory care. 2015. DOI: 10.4187/respcare.03875.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.