MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11517-015-1399-z

Медицинская библиотека · Medical & biological engineering & computing · 2015

Numerical simulation of pharyngeal airflow applied to obstructive sleep apnea: effect of the nasal cavity in anatomically accurate airway models.

Cisonni Julien, Lucey Anthony D, King Andrew J C, Islam Syed Mohammed Shamsul, Lewis Richard, Goonewardene Mithran S

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Repetitive brief episodes of soft-tissue collapse within the upper airway during sleep characterize obstructive sleep apnea (OSA), an extremely common and disabling disorder. Failure to maintain the patency of the upper airway is caused by the combination of sleep-related loss of compensatory dilator muscle activity and aerodynamic forces promoting closure. The prediction of soft-tissue movement in patient-specific airway 3D mechanical models is emerging as a useful contribution to clinical understanding and decision making. Such modeling requires reliable estimations of the pharyngeal wall pressure forces. While nasal obstruction has been recognized as a risk factor for OSA, the need to include the nasal cavity in upper-airway models for OSA studies requires consideration, as it is most often omitted because of its complex shape. A quantitative analysis of the flow conditions generated by the nasal cavity and the sinuses during inspiration upstream of the pharynx is presented. Results show that adequate velocity boundary conditions and simple artificial extensions of the flow domain can reproduce the essential effects of the nasal cavity on the pharyngeal flow field. Therefore, the overall complexity and computational cost of accurate flow predictions can be reduced.

Для цитирования: Cisonni Julien, Lucey Anthony D, King Andrew J C, Islam Syed Mohammed Shamsul, Lewis Richard, Goonewardene Mithran S. Numerical simulation of pharyngeal airflow applied to obstructive sleep apnea: effect of the nasal cavity in anatomically accurate airway models.. Medical & biological engineering & computing. 2015. DOI: 10.1007/s11517-015-1399-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.