STUDY

OBJECTIVE

To investigate the isolated and combined effects of vacuum suctioning and strategic drape tenting on oxygen concentration in an experimental setting.

DESIGN

Experimental.

SETTING

Clinical simulation center of a university-affiliated hospital.

PARTICIPANTS

Mannequin simulation of a patient undergoing facial surgery under sedation anesthesia. Supplemental oxygen was delivered via nasal cannula.

INTERVENTIONS: Vacuum suctioning and strategic drape tenting.

MEASUREMENTS: The experimental trials entailed measuring oxygen concentration around the nasal cannula continuously either in the presence or absence of a standard operating room vacuum suction system and strategic tenting of surgical drapes. The primary outcome was the time required for oxygen concentration to reach 21%.

MAIN

RESULTS

In the control group (without suction or strategic tenting), a mean time of 180 seconds elapsed until the measured oxygen concentration reached 21% after cessation of oxygen delivery. Use of a vacuum suction device alone (110 seconds; P < .01) or in combination with strategic tenting (110 seconds; P < .01) significantly reduced this time. No significant benefit was seen when tenting was used alone (160 seconds; P < .30).

CONCLUSION

Use of a vacuum suction device during surgery will lower local oxygen concentration, and this in turn may decrease the risk of operating room fires. Although strategic tenting of surgical drapes has a theoretical benefit to decreasing the pooling of oxygen around the surgical site, further investigation is necessary before its routine use is recommended.

Для цитирования: Kung Theodore A, Kong Sarah W, Aliu Oluseyi, Azizi Jahan, Kai Salim, Cederna Paul S. Effects of vacuum suctioning and strategic drape tenting on oxygen concentration in a simulated surgical field.. Journal of clinical anesthesia. 2015. DOI: 10.1016/j.jclinane.2015.08.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.