Evaluation of Low-Dose Multidetector Computed Tomography Whole Gastroenterography With Oral Administration of Contrast Agents.
Аннотация
PURPOSE: To evaluate the degree of gastric, enteric, colonic, and rectal filling in multidetector computed tomography (MDCT) whole gastroenterography.
METHODS
In this prospective study involving 124 patients, 78 and 46 patients underwent MDCT whole gastroenterography using positive and neutral oral contrast agents, respectively. The degree of filling of the stomach, small and large bowel, was qualitatively analyzed by experienced radiologists using a 3-point scoring system.
RESULTS
The majority of patients received a score of ≥2 for small intestine filling using both positive and neutral contrast agents (90.5% and 78.2%, respectively), and <9% of the patients had a score of 0. The highest score for the degree of filling in the small intestine was observed in the ileum, followed by the duodenum and jejunum. There was a significant difference in the degree of filling achieved with positive and neutral contrast agents in the duodenum (P = .013) and jejunum (P = .047). More than 74% of cases had an optimal filling of the stomach, whereas >80% of the cases had an optimal filling of the colorectal segments. Only ≤5.1% had a score of 0 for the analyzed segments of the colorectum. Positive and neutral contrast agents were associated with similar degree of filling in the stomach and colon segments without a significant difference in the extent of contrast agent filling (P > .05).
CONCLUSIONS
Multidetector computed tomography whole gastroenterography was found to be a simple, safe, noninvasive, painless, and effective modality for the diagnosis of stomach and bowel complications in clinical settings.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.