MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/lary.26802

Медицинская библиотека · The Laryngoscope · 2017

Development and validation of an endoscopic ear surgery classification system.

Cohen Michael S, Basonbul Razan A, Barber Samuel R, Kozin Elliott D, Rivas Alejandro C, Lee Daniel J

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES/HYPOTHESIS: To design and validate a classification system for endoscopic ear surgery.

STUDY

DESIGN

Validation study.

METHODS

A classification system was devised that quantifies use of the endoscope during middle ear surgery. Otologic operative reports were reviewed by attending surgeons and trainees. A power analysis was performed to determine number of cases needed to review. The following categories were used: class 0 is defined by using the microscope only; class 1 describes the use of endoscope for inspection without dissection; and class 2 describes mixed use of the endoscope and the microscope. It is further subdivided into 2a and 2b, where the endoscope is used for less than 50% of dissection and more than 50% of dissection, respectively. Class 3 describes the use of the endoscope for the entire surgery. Fifty cases were reviewed by three attending otologic surgeons, one resident, and one medical student.

RESULTS

Weighted Cohen's Kappa for inter-rater agreement between the two institutional surgeons was 0.79 (95% bias corrected [BC] confidence interval [CI]: 0.58-0.93). Agreement between the external surgeon and the two institutional surgeons was 0.77 (95% BC CI: 0.58-0.89) and 0.76 (95% BC CI: 0.57-0.88). Weighted Kappa between institutional surgeons and a resident was 0.73 (95% BC CI: 0.53-0.88) and 0.62 (95% BC CI: 0.38-0.80), and between institutional surgeons and a medical student was 0.75 (95% BC CI: 0.56-0.89) and 0.70 (95% BC CI: 0.49-0.85).

CONCLUSIONS

There was substantial inter-rater agreement. This classification system can be used as a simple and reliable tool to describe the extent to which an endoscope was used during ear surgery.

LEVEL OF EVIDENCE: NA. Laryngoscope, 128:967-970, 2018.

Для цитирования: Cohen Michael S, Basonbul Razan A, Barber Samuel R, Kozin Elliott D, Rivas Alejandro C, Lee Daniel J. Development and validation of an endoscopic ear surgery classification system.. The Laryngoscope. 2017. DOI: 10.1002/lary.26802.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.