MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1600-0501.2012.02421.x

Медицинская библиотека · Clinical oral implants research · 2012

Maxillary sinus floor augmentation with injectable calcium phosphate cements: a pre-clinical study in sheep.

Hoekstra Jan Willem M, Klijn Reinoud J, Meijer Gert J, van den Beucken Jeroen J J P, Jansen John A

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this pre-clinical study was to evaluate the biological performance of two injectable calcium phosphate cement (CPC) composite materials containing poly(D,L-lactic-co-glycolic)acid (PLGA) microspheres with different properties in a maxillary sinus floor elevation model in sheep.

MATERIALS AND

METHODS

PLGA microspheres were made of either low molecular weight (~17 kDa) acid-terminated PLGA (PLGA(L-AT) ) or high molecular weight (~44 kDa) end-capped PLGA (PLGA(H-EC) ) and incorporated in CPC. Eight female Swifter sheep underwent a bilateral maxillary sinus floor elevation procedure via an extra-oral approach. All animals received both materials, alternately injected in the left and right sinus (split-mouth model) and a time point of 12 weeks was used. Analysis of biological performance was based on histology, histomorphometry, and evaluation of sequential fluorochrome labeling.

RESULTS

Both types of CPC-PLGA composites showed biocompatibility and direct bone-cement contact. CPC-PLGA(L-AT) showed a significantly higher degradation distance compared to CPC-PLGA(H-EC) (1949 ± 1295 μm vs. 459 ± 267 μm; P = 0.0107). Further, CPC-PLGA(L-AT) showed significantly more bone in the region of interest (26.4 ± 10.5% vs. 8.6 ± 3.9% for PLGA(H-EC) ; P = 0.0009) and significantly less remaining CPC material (61.2 ± 17.7% vs. 81.9 ± 10.9% for PLGA(H-EC) ; P = 0.0192).

CONCLUSIONS

Both CPC-PLGA(L-AT) and CPC-PLGA(H-EC) demonstrated to be safe materials for sinus floor elevation procedures in a large animal model, presenting biocompatibility and direct bone contact. In view of material performance, CPC-PLGA(L-AT) showed significantly faster degradation and a significantly higher amount of newly formed bone compared to CPC-PLGA(H-EC) .

Для цитирования: Hoekstra Jan Willem M, Klijn Reinoud J, Meijer Gert J, van den Beucken Jeroen J J P, Jansen John A. Maxillary sinus floor augmentation with injectable calcium phosphate cements: a pre-clinical study in sheep.. Clinical oral implants research. 2012. DOI: 10.1111/j.1600-0501.2012.02421.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.