m+Medelevator.RU
← Поиск публикаций
Medical physics · 2023

Robot-assisted augmented reality surgical navigation based on optical tracking for mandibular reconstruction surgery.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shao Long, Li Xing, Fu Tianyu, Meng Fanhao, Zhu Zhihui, Zhao Ruiqi, Huo Minghao, Xiao Deqiang, Fan Jingfan, Lin Yucong, Zhang Tao, Yang Jian

Аннотация

PURPOSE: This work proposes a robot-assisted augmented reality (AR) surgical navigation system for mandibular reconstruction. The system accurately superimposes the preoperative osteotomy plan of the mandible and fibula into a real scene. It assists the doctor in osteotomy quickly and safely under the guidance of the robotic arm.

METHODS: The proposed system mainly consists of two modules: the AR guidance module of the mandible and fibula and the robot navigation module. In the AR guidance module, we propose an AR calibration method based on the spatial registration of the image tracking marker to superimpose the virtual models of the mandible and fibula into the real scene. In the robot navigation module, the posture of the robotic arm is first calibrated under the tracking of the optical tracking system. The robotic arm can then be positioned at the planned osteotomy after the registration of the computed tomography image and the patient position. The combined guidance of AR and robotic arm can enhance the safety and precision of the surgery.

RESULTS: The effectiveness of the proposed system was quantitatively assessed on cadavers. In the AR guidance module, osteotomies of the mandible and fibula achieved mean errors of 1.61 ± 0.62 and 1.08 ± 0.28 mm, respectively. The mean reconstruction error of the mandible was 1.36 ± 0.22 mm. In the AR-robot guidance module, the mean osteotomy errors of the mandible and fibula were 1.47 ± 0.46 and 0.98 ± 0.24 mm, respectively. The mean reconstruction error of the mandible was 1.20 ± 0.36 mm.

CONCLUSIONS: The cadaveric experiments of 12 fibulas and six mandibles demonstrate the proposed system's effectiveness and potential clinical value in reconstructing the mandibular defect with a free fibular flap.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты