Correlation of MRCP quantification (MRCPQ) with conventional non-invasive pancreatic exocrine function tests.

Gillams Alice, Pereira Stephen, Webster George, Lees William

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To correlate MRCP quantification (MRCPQ) of pancreatic fluid output following secretin with steatorrhoea, urinary pancreo-lauryl (PL) or fecal elastase 1 (FE1) tests.

METHODS AND MATERIALS: Sixty-one patients, 36 male, median age 51 years (23-78) with known or suspected pancreatic disease who had undergone both MRCPQ and FE1 or PL were included. Twenty-nine patients had chronic pancreatitis, five acute pancreatitis, seven normal, five pancreas divisum, four pancreatic atrophy, three pancreatic duct obstruction, two post-surgical and six miscellaneous diagnoses. Clinical assessment of steatorrhoea was available in 29. MRCP was performed before and at 2 min intervals after 0.1 ml/kg IV Secretin. Changes in signal intensity in the imaging volume were plotted against time and the flow rate derived from the gradient. Scatter plots, Pearson correlation coefficient, and the Fisher Exact test were performed.

RESULTS

MRCPQ was significantly different (p = 0.012) between those with/without steatorrhoea; mean +/- SD (95% CI) were 4.0 +/- 1.5 (3.1:4.9, n = 16) and 6.3 +/- 2.9 (4.7:7.8, n = 13). Fifty-one paired FE1-MRCPQ and 24 PL-MRCPQ data sets were analysed. Both the Pearson correlation coefficient (FE1 p = 0.001 and %TK p = 0.003) and the Fisher Exact test were significant (FE1 p = 0.016 and %T/K 0.03).

CONCLUSIONS

MRCPQ correlated with steatorrhoea, PL and FE1.

Для цитирования: Gillams Alice, Pereira Stephen, Webster George, Lees William. Correlation of MRCP quantification (MRCPQ) with conventional non-invasive pancreatic exocrine function tests.. Abdominal imaging. 2008. DOI: 10.1007/s00261-007-9286-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.