MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2026.09.005

Медицинская библиотека · The Annals of thoracic surgery · 2026

Hybrid Arch Stent Graft in the Treatment of Acute and Chronic Aortic Pathologies: Interim Results from an Asia-Pacific Multi-center study.

Song Suk Won, Park Kay Hyun, Kim Tae Hoon, Tang David, Sorokin Vitaly A, Slisatkorn Worawong, Moorthy Paneer Selvam Krishna, Matalanis George, Ho Cally, Ho Jacky Y K, Wong Randolph H L

СтатьяПеревод в очереди

Аннотация

BACKGROUND

NEOS-APAC is an observational, prospective, multicenter post-market study in Asia Pacific to demonstrate the safety and clinical performance of the E-vita OPEN NEO for frozen elephant treatment (FET) of aneurysms or dissections. This article reports the first interim results until 3-6 months.

METHODS

Overall, 114 patients were enrolled in ten Asia Pacific sites between August 2021 - February 2024. Of those, 112 (mean age 59±11 years, 81% male) underwent device placement. Of these, 98% reached discharge and 90% 3-6 months follow-up. The E-vita OPEN NEO was implanted per treating physician discretion and per the Instructions For Use. The 112 patients were distributed among three different indications (34%/7% acute/subacute aortic dissection, 26% chronic aortic dissection and 33% thoracic aortic aneurysm).

RESULTS

The 30-day mortality (primary endpoint) was 1.8% and all-cause mortality was 3.6% until 180 days. None of the deaths were evaluated as device-related. At discharge technical success was achieved in 97.3% and treatment success reached 95.0% at 3-6 months. Secondary endpoints included 0% aortic-related death or rupture and 0% loss of device integrity at 3-6 months. Patients experienced 0.9% new disabling stroke, 0.9% new paraplegia and 1.8% new paraparesis until discharge, and 3.0%, 2.0% and 2.0% until 3-6 months, respectively. No patients had renal failure.

CONCLUSIONS

The NEOS-APAC study yields promising early follow-up results with a low 30-day mortality rate and low main secondary safety outcome rates, which compare favorably to literature. The results demonstrate safe and effective treatment with the E-vita OPEN NEO in the Asia Pacific clinical setting.

Для цитирования: Song Suk Won, Park Kay Hyun, Kim Tae Hoon, Tang David, Sorokin Vitaly A, Slisatkorn Worawong, Moorthy Paneer Selvam Krishna, Matalanis George, Ho Cally, Ho Jacky Y K, Wong Randolph H L. Hybrid Arch Stent Graft in the Treatment of Acute and Chronic Aortic Pathologies: Interim Results from an Asia-Pacific Multi-center study.. The Annals of thoracic surgery. 2026. DOI: 10.1016/j.athoracsur.2026.09.005.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.