DOI 10.1016/j.ejso.2016.08.014
Robotic single site staging in endometrial cancer: A multi-institution study.
Аннотация
OBJECTIVE
To evaluate the feasibility and the safety of robotic single site hysterectomy (RSSH) plus or less pelvic lymphadenectomy in FIGO stage I-II endometrial cancer.
MATERIALS AND
METHODS
We prospectively collected patient demographics, operative times, complications, pathologic results, and length of stay on all patients who underwent RSSH plus or less pelvic lymphadenectomy for clinical FIGO stage I or occult stage II endometrial carcinoma.
RESULTS
From January 2012 to February 2015, 125 patients were included in our study. The median age of the patients was 59 years (range, 35-84 years) and the median body mass index was 27 kg/m(2) (range, 19-52 kg/m(2)). One patient was converted to vaginal surgery due to problems of hypercapnia. The median docking time, console time, and total operative time was 11 min (range, 4-40 min), 80 min (range, 20-240 min) and 122 min (range, 35-282 min), respectively. The median blood loss was 50 ml (range, 10-250 ml). No laparoscopic/laparotomic conversion was registered. Twenty one patients underwent pelvic lymphadenectomy (16.8%) and the median pelvic lymph nodes was 13 (range, 3-32). The median time to discharge was 2 days (range, 1-3 days). No intra-operative complications occurred, while we observed 10 (8%) early post-operative complications.
CONCLUSION
RSSH plus or less pelvic lymphadenectomy is technically feasible, safe and reproducible and could be the treatment of choice for patients affected by FIGO stage I-II endometrial cancer. However, randomized controlled trials are needed to confirm these results.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.