MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10334-024-01167-6

Медицинская библиотека · Magma (New York, N.Y.) · 2024

Quantitative 23Na magnetic resonance imaging in the abdomen at 3 T.

Birchall Jonathan Richard, Horvat-Menih Ines, Kaggie Joshua Daniel, Riemer Frank, Benjamin Arnold Julian Vinoj, Graves Martin John, Wilkinson Ian, Gallagher Ferdia Aidan, McLean Mary Anne

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To assess the feasibility of sodium-23 MRI for performing quantitative and non-invasive measurements of total sodium concentration (TSC) and relaxation in a variety of abdominal organs.

MATERIALS AND

METHODS

Proton and sodium imaging of the abdomen was performed in 19 healthy volunteers using a 3D cones sequence and a sodium-tuned 4-rung transmit/receive body coil on a clinical 3 T system. The effects of B1 non-uniformity on TSC measurements were corrected using the double-angle method. The long-component of 23Na T2* relaxation time was measured using a series of variable echo-times.

RESULTS

The mean and standard deviation of TSC and long-component 23Na T2* values were calculated across the healthy volunteer group in the kidneys, cerebrospinal fluid (CSF), liver, gallbladder, spleen, aorta, and inferior vena cava.

DISCUSSION: Mean TSC values in the kidneys, liver, and spleen were similar to those reported using 23Na-MRI previously in the literature. Measurements in the CSF and gallbladder were lower, potentially due to the reduced spatial resolution achievable in a clinically acceptable scan time. Mean long-component 23Na T2* values were consistent with previous reports from the kidneys and CSF. Intra-population standard error was larger in smaller, fluid-filled structures due to fluid motion and partial volume effects.

Для цитирования: Birchall Jonathan Richard, Horvat-Menih Ines, Kaggie Joshua Daniel, Riemer Frank, Benjamin Arnold Julian Vinoj, Graves Martin John, Wilkinson Ian, Gallagher Ferdia Aidan, McLean Mary Anne. Quantitative 23Na magnetic resonance imaging in the abdomen at 3 T.. Magma (New York, N.Y.). 2024. DOI: 10.1007/s10334-024-01167-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.