DOI 10.1016/j.transci.2023.103821
The effect of cryopreservation on engraftment kinetics in fully matched allogeneic stem cell transplantation: Real-life data and literature review.
Аннотация
INTRODUCTION
The standard approach for allogeneic stem cell transplantation (allo-SCT) is to administer donor cells on the same day as a fresh product to a patient who has been given a preparative regimen. The difficulty in collecting and transporting donor cells, especially during the COVID-19 pandemic, has made it essential to collect and cryopreserve the grafts before the recipient begins the transplant preparation regimen. However, the short- and long-term impacts of cryopreservation on transplant outcomes remain controversial.
MATERIALS AND
METHODS
This retrospective study included 93 patients who underwent allo-SCT between January 2012 and August 2022 at the Stem Cell Transplant Unit of Bursa Uludag University Faculty of Medicine using frozen and fresh products of peripheral blood stem cells from a fully matched sibling donor. The effect of cryopreservation of donor grafts on engraftment kinetics was investigated.
RESULTS
Frozen and fresh products were used in 37 and 56 patients, respectively. The majority of patients had acute myeloid leukemia and acute lymphoblastic leukemia. The median age at transplantation was 41 years. Neutrophil engraftment time was similar between the two groups (median: 14 vs. 16 days, p = 0.393). Platelet engraftment time was longer in the frozen product group (median: 12 vs. 15 days, p < 0.001). There was no statistically significant difference between freezing time and viability. The acute graft-versus-host disease (GVHD) rate was 37.8 % in the frozen product group and 28.6 % in the fresh product group (p = 0.349). There was no significant difference between the two groups in terms of primary and secondary graft failure, chronic GVHD, 30-day chimerism, relapse, overall survival, progression-free survival, and nonrelapse mortality.
CONCLUSION
Having donor cells ready before transplantation significantly prevents donor-induced adverse events and provides confidence and practicality to both the clinician and the recipient. Allo-SCT with frozen products is a successful method that can be safely applied, especially when disruptions in donor-derived cell collection or transportation are foreseen.