Use of electronic health records to examine margin-to-reflex distance in patients without eyelid conditions affecting position.
Аннотация
PURPOSE: To characterize reference margin-to-reflex distance 1 (MRD1) measurements across different demographic factors, age, sex, race, and ethnicity, using a large electronic health record-derived (EHR) dataset.
METHODS
This was a single-institution observational, cross-sectional study of adult patients seen in an academic oculoplastics division from October 2018 to June 2023. MRD1 values were extracted from structured data fields and free-text progress notes. Patients with diagnoses known to affect MRD1 (e.g. dermatochalasis, ptosis) were excluded from the study. Univariate analysis was conducted using one-way ANOVA and post hoc testing, while multivariable analysis testing was done through a linear mixed-effects regression model.
RESULTS
A total of 6231 patients and 11,932 reference MRD1 values were analyzed. MRD1 decreased by approximately 0.2 mm (mm) per decade of life (p < 0.001). Female sex was associated with higher MRD1 measurements (3.38 vs 3.003, p < 0.001), while Asian race was associated with lower MRD1 values (2.99 vs 3.32, p < 0.001).
CONCLUSIONS
MRD1 values vary significantly by age, sex, and race. These findings provide reference values for MRD1 within a clinical oculoplastics population accounting for demographic factors.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.