MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clbc.2022.01.003

Медицинская библиотека · Clinical breast cancer · 2022

Magnetic Seeds: An Alternative to Wire Localization for Nonpalpable Breast Lesions.

Kelly Bridget N, Webster Alexandra J, Lamb Leslie, Spivey Tara, Korotkin Jenna E, Henriquez Anthony, Gadd Michele A, Hughes Kevin S, Lehman Constance R, Smith Barbara L, Specht Michelle C

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Magnetic seeds have emerged as an alternative to wires for localization of nonpalpable breast lesions. The purpose of this study was to evaluate the utility of magnetic seeds compared to wires for preoperative localization.

MATERIALS AND

METHODS

A retrospective cohort analysis of magnetic seed localization (MSL) and wire localization (WL) excisional biopsies and lumpectomies performed at a single institution was conducted. Indication, age, BMI, number of markers, procedure type, operative time, and postoperative opioid administration were reviewed. Impact of localization method on operative time, specimen volume, postoperative opioid administration, and re-excision rate were assessed.

RESULTS

A total of 608 MSL procedures in 601 patients were compared to 628 WL procedures in 620 patients. MSL excisional biopsies were significantly longer (37.0 minutes) than WL excisional biopsies (31.9 minutes, P< .001), but in lumpectomies without axillary surgery, MSL procedures (42.3 minutes) were significantly shorter than WL procedures (46.9 minutes, P = .017). Significantly less tissue was excised during MSL lumpectomies (68.5 cm3) and excisional biopsies (32.3 cm3) than WL lumpectomies (78.1 cm3, P = .039) and excisional biopsies (38.7 cm3, P = .018). Postoperative opioid administration was similar for MSL and WL procedures (P = .076). Re-excision rates for MSL lumpectomies were significantly higher for ductal carcinoma in situ (35.3% MSL vs. 18.5% WL, P = .013), but were similar for invasive carcinoma (14.4% MSL vs. 17.7% WL, P = .290). Logistic regression analysis showed no association between localization method and re-excision (OR 1.007, 95% CI 0.681-1.488; P = .973).

CONCLUSION

MSL is a feasible alternative to WL for excision of nonpalpable breast lesions with regard to surgical outcomes.

Для цитирования: Kelly Bridget N, Webster Alexandra J, Lamb Leslie, Spivey Tara, Korotkin Jenna E, Henriquez Anthony, Gadd Michele A, Hughes Kevin S, Lehman Constance R, Smith Barbara L, Specht Michelle C. Magnetic Seeds: An Alternative to Wire Localization for Nonpalpable Breast Lesions.. Clinical breast cancer. 2022. DOI: 10.1016/j.clbc.2022.01.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.