MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/a-2576-5837

Медицинская библиотека · Endoscopy international open · 2025

Ex vivo evaluation of a novel through-the-scope traction device for endoscopic submucosal dissection.

Alfarone Ludovico, De Sire Roberto, Rosenbaum Boris, Aidibi Ali, Cellier Christophe, Hassan Cesare, Repici Alessandro, Rahmi Gabriel, Maselli Roberta

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND STUDY AIMS: Endoscopic submucosal dissection (ESD) is a technique used for resection of large neoplastic lesions, providing great oncological outcomes. However, ESD is technically challenging with a long learning curve, high complication rates, and extended procedure times. To address these limitations, various traction-assisted methods have been developed. This study evaluated a novel through-the-scope traction device (TRACMOTION, Fujifilm, Japan), which offers consistent and adjustable traction, in a pilot multicenter randomized ex vivo trial.

PATIENTS AND

METHODS

The study included six endoscopists with limited ESD experience performing ESD on ex vivo porcine stomach models. Participants were randomized into two groups: those using TRACMOTION-assisted ESD (TM-ESD) and those performing conventional ESD (C-ESD). Each trainee completed six procedures, split equally between both groups. The primary outcome was resection speed, whereas secondary outcomes included en bloc, R0 resection rates, perforation rates, and rates of speedy procedures (>20 mm²/min).

RESULTS

The TM-ESD group achieved a higher median resection speed of 20.75 mm²/min (95% confidence interval [CI] 14.56-29.25) in comparison to 15.10 mm²/min (95% CI 12.8-16.6) in the C-ESD group ( P =0.02). Perforation rates were significantly lower in the TM-ESD group (11.1% (95% CI 0.01-0.34) vs. 61.1% (95% CI 0.35-0.82; P =0.0002). No significant differences were observed in en bloc or R0 resection rates between the groups.

CONCLUSIONS

TRACMOTION significantly improves the efficiency of ESD, reducing procedure time and complication rates. This traction device could potentially facilitate broader adoption of ESD in clinical practice. However, further research in human trials is necessary to validate these findings.

Для цитирования: Alfarone Ludovico, De Sire Roberto, Rosenbaum Boris, Aidibi Ali, Cellier Christophe, Hassan Cesare, Repici Alessandro, Rahmi Gabriel, Maselli Roberta. Ex vivo evaluation of a novel through-the-scope traction device for endoscopic submucosal dissection.. Endoscopy international open. 2025. DOI: 10.1055/a-2576-5837.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.