DOI 10.2147/opth.s48914

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2013

Meta-analysis of the ocular biocompatibility of a new multipurpose lens care system.

Reindel William, Merchea Mohinder M, Rah Marjorie J, Zhang Lening

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The purpose of this paper is to evaluate the biocompatibility of a novel multipurpose solution (MPS) with a dual disinfectant system containing polyaminopropyl biguanide and polyquaternium-1 (Biotrue®) by analysis of biomicroscopy signs and adverse events in six large clinical trials.

METHODS

Data from six consecutive, prospective clinical trials conducted from February 2008 to March 2010 were combined for meta-analysis. Subjects used the new MPS daily for periods of 2 weeks to 6 months. Slit-lamp signs were graded at each follow-up visit using an ordinal scale (0, one; 1, trace; 2, mild; 3, moderate; 4, severe). Analysis for biocompatibility included tracking of greater than grade 2 slit-lamp findings and number of adverse events.

RESULTS

A total of 1,567 subjects (3,134 eyes) and 81 clinical investigators participated in the six studies, with 1,499 subjects completing the studies. Based on subject days in the studies, there were 72,904 exposures to the MPS and 7,212 biomicroscopy examinations. The completion rate for the studies was 96.3%. Per observation incidence of any finding greater than grade 2 at the follow-up visits were: corneal staining 0.08%, limbal injection 0.04%, bulbar injection 0.04%, tarsal conjunctiva abnormality 0.09%, and neovascularization 0.01%. There were no other slit-lamp signs greater than grade 2 and no statistically significant difference between hydrogels and silicone hydrogels for any finding. There were no reports of adverse events during the trials.

CONCLUSION

Analysis of over 72,000 daily exposures and 7,212 eye examinations showed that the novel MPS exhibited excellent biocompatibility in subjects using daily wear hydrogel or silicone hydrogel lenses.

Для цитирования: Reindel William, Merchea Mohinder M, Rah Marjorie J, Zhang Lening. Meta-analysis of the ocular biocompatibility of a new multipurpose lens care system.. Clinical ophthalmology (Auckland, N.Z.). 2013. DOI: 10.2147/opth.s48914.