m+Medelevator.RU
← Поиск публикаций
Cancers · 2025

Diagnostic Accuracy and Interrater Agreement of FDG-PET/CT Lymph Node Staging in High-Risk Endometrial Cancer: The SENTIREC-Endo Study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Holm Jorun, Dias André Henrique, Gerke Oke, Loft Annika, Bouchelouche Kirsten, Vilstrup Mie Holm, Bjørnholt Sarah Marie, Sponholtz Sara Elisabeth, Jochumsen Kirsten Marie, Hildebrandt Malene Grubbe, Jensen Pernille Tine

Аннотация

Background/Objectives: The SENTIREC-endo study identified a safe sentinel lymph node mapping algorithm combined with PET-positive node dissection, matching radical pelvic and paraaortic lymphadenectomy in high-risk endometrial cancer. The present study evaluated the diagnostic accuracy of FDG-PET/CT for lymph node metastases in the same population based on location, size, and Standardised Uptake Value (SUV), in addition to assessing interrater agreement across three Danish centres. Methods: This prospective multicentre study included women with high-risk endometrial cancer from the Danish SENTIREC study database (2017-2023). All patients underwent preoperative FDG-PET/CT. Diagnostic accuracy was evaluated against a pathology-confirmed reference standard. Interrater agreement was evaluated between trained specialists in Nuclear Medicine. Results: Among 227 patients, 52 patients (23%) had lymph node metastases. FDG-PET/CT identified lymph node metastases with 56% sensitivity (95% CI: 42-68) and 91% specificity (95% CI: 86-94). Positive and negative predictive values were 64% and 87%, respectively. Specificity for paraaortic nodes was high (97%), though sensitivity remained limited (56%). Lymph node size and SUVmax had moderate diagnostic value (AUC-ROC ~0.7). Interrater proportion of agreement was 95% and Cohen's Kappa κ = 0.84 (95% CI: 0.73-0.94), the latter of which was 'almost perfect'. Conclusions: FDG-PET/CT had limited sensitivity in lymph node staging in high-risk EC, and the diagnostic accuracy of FDG-PET/CT remains complementary to the sentinel node procedure. Due to its high specificity and strong interrater reliability, FDG-PET/CT is recommended for clinical implementation in combination with the sensitive sentinel node biopsy for the targeted dissection of PET-positive lymph nodes, particularly in paraaortic regions.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты