European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2016
Method to test the long-term stability of functional electrical stimulation via multichannel electrodes (e.g., applicable for laryngeal pacing) and to define best points for stimulation: in vivo animal analysis.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Faenger Bernd, Arnold Dirk, Schumann Nikolaus P, Guntinas-Lichius Orlando, Scholle Hans-Christoph
Аннотация
The study aim was to identify and analyze intramuscular electrically sensitive points. Electrically sensitive points are herein defined as positions, which allow muscles stimulation with a minimum possible fatigue for a maximum amount of time. A multichannel array electrode was used which could be interesting to retain the function of larynx muscle after paralysis. Eight array electrodes were implanted in the triceps brachii muscle of four rats. While being under anesthesia, the animals were intramuscularly stimulated at 16 different positions. Sihler's staining technique was used to make visible the nerves routes and the intramuscular position of the individual electrode plate. The positions of the motor end plates were determined by means of multichannel-electromyography. The positions that allow longest stimulation periods are located close to the points where the nerves enter the muscle. Stimulation at the position of the motor end plates does not result in stimulation periods above average. Locations initially causing strong muscle contractions are not necessarily identical to the ones allowing long stimulation periods. The animal model identified the stimulation points for minimal possible muscle fatigue stimulation as being located close to the points of entrance of the nerve into the muscle. Stimulation causing an initially strong contraction response is no indication of optimal location of the stimulation electrode in terms of chronic stimulation. The array electrode of this study could be interesting as a stimulation electrode for a larynx pacemaker.