DOI 10.1097/apo.0000000000000345
Optical Coherence Tomography Angiography Assessment of Macular Choriocapillaris and Choroid Following Panretinal Photocoagulation in a Diverse Population With Advanced Diabetic Retinopathy.
Аннотация
PURPOSE: The aim of this study was to evaluate choroidal and retinal microvasculature with optical coherence tomography angiography (OCTA) after panretinal photocoagulation (PRP) for diabetic retinopathy in a primarily Hispanic and Asian population.
DESIGN
Retrospective study.
METHODS
Eyes were examined by OCTA in the macula (3 × 3 mm) just before PRP treatment and 1 to 3 months afterwards. Choroidal thickness (CT) and central retinal thickness (CRT) were measured. Choroidal flow signal voids (CFSV) and choriocapillaris flow signal voids (CCFSV) were acquired. Retinal microvasculature parameters, including superficial and deep vessel density, superficial and deeper perfusion density, foveal avascular zone area, perimeter and circularity, were calculated. Ocular examinations and demographic information were analyzed.
RESULTS
CT at a location 1000 μm temporal to the fovea increased significantly after PRP (from 278.64 μm to 313.44 μm, P = 0.026). CCFSV increased slightly from (46.72 ± 8.52)% to (47.07 ± 10.77)%, but the difference was not statistically significant (P = 0.782). A similar finding was observed in CFSV (increase from 35.81% to 36.64%, P = 0.165). The change in all retinal microvasculature parameters was also not significant. Best-corrected visual acuity (BCVA) decreased from 0.218 ± 0.153 to 0.262 ± 0.147 (P = 0.034). Increased CRT (from 245.41 ± 33.18 μm to 251.14 ± 38.97 μm, P = 0.007) was observed. The change in CRT positively correlated with pre-PRP CRT (r = 0.434, P = 0.019) and BCVA reduction (r = 0.418, P = 0.024). Neither BCVA reduction nor CRT increase correlated with OCTA metrics.
CONCLUSIONS
OCTA demonstrates redistribution of choroidal circulation from the periphery to the macula after PRP, with increased macular CT and stable choroidal blood flow density. Eyes with greater macular thickness are more likely to experience an increase in CRT.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.