Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2017
Prognosis of high sinus heart rate after catheter ablation for atrial fibrillation.
СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yu Hee Tae, Kim Tae-Hoon, Uhm Jae-Sun, Kim Jong-Youn, Joung Boyoung, Lee Moon-Hyoung, Pak Hui-Nam
Аннотация
AIMS: Although atrial fibrillation (AF) catheter ablation increases sinus heart rate (HR), its mechanism and prognosis have not yet been clearly elucidated. We hypothesize that post-AF ablation high sinus HR (PA-HSR) is associated with a better clinical outcome of AF ablation without adverse cardiac effects.
METHODS AND RESULTS: We studied 991 AF patients (75% male, 58 ± 11 years old, 70% paroxysmal AF) with HR variability (HRV) at 3 months and 1 year after catheter ablation, and pre- and post-1-year echocardiograms. Post-AF ablation high sinus HR was defined as an average HR greater than 2 SD (≥92 bpm) as measured by 24 h Holter. (1) Average HR increased significantly (P< 0.001), and PA-HSR was observed in 28 patients (2.8%) 3 months after AF ablation. At 1 year after catheter ablation, 21% were taking β-blockers and 36% maintained an average HR of ≥92 bpm. (2) Post-AF ablation high sinus HR was independently associated with pre-procedural high average HR (OR 1.097; 95% CI 1.029-1.169, P= 0.005), high left atrium (LA) electrogram voltage (OR 3.545; 95% CI 1.183-10.618, P= 0.024), and reduced root mean square of differences between successive NN intervals (rMSSD) at 3 months HRV (OR 0.959; 95% CI 0.919-0.999, P= 0.047). (3) At 1 year echocardiography, size reduction of LA (P= 0.055) or LV (P= 0.372) and the improvement in ejection fraction (P= 0.529) were not significantly different between patients with PA-HSR and those without. (4) Throughout 27 ± 17 months of follow-up, patients with PA-HSR showed significantly lower clinical recurrence than those without (log rank, P= 0.020).
CONCLUSION: Post-AF ablation high sinus HR was observed in patients with smaller LA size and higher LA electrogram voltage and significant vagal modulation without adverse cardiac effects. Post-AF ablation high sinus HR was associated with a significantly lower clinical recurrence of AF after catheter ablation.
METHODS AND RESULTS: We studied 991 AF patients (75% male, 58 ± 11 years old, 70% paroxysmal AF) with HR variability (HRV) at 3 months and 1 year after catheter ablation, and pre- and post-1-year echocardiograms. Post-AF ablation high sinus HR was defined as an average HR greater than 2 SD (≥92 bpm) as measured by 24 h Holter. (1) Average HR increased significantly (P< 0.001), and PA-HSR was observed in 28 patients (2.8%) 3 months after AF ablation. At 1 year after catheter ablation, 21% were taking β-blockers and 36% maintained an average HR of ≥92 bpm. (2) Post-AF ablation high sinus HR was independently associated with pre-procedural high average HR (OR 1.097; 95% CI 1.029-1.169, P= 0.005), high left atrium (LA) electrogram voltage (OR 3.545; 95% CI 1.183-10.618, P= 0.024), and reduced root mean square of differences between successive NN intervals (rMSSD) at 3 months HRV (OR 0.959; 95% CI 0.919-0.999, P= 0.047). (3) At 1 year echocardiography, size reduction of LA (P= 0.055) or LV (P= 0.372) and the improvement in ejection fraction (P= 0.529) were not significantly different between patients with PA-HSR and those without. (4) Throughout 27 ± 17 months of follow-up, patients with PA-HSR showed significantly lower clinical recurrence than those without (log rank, P= 0.020).
CONCLUSION: Post-AF ablation high sinus HR was observed in patients with smaller LA size and higher LA electrogram voltage and significant vagal modulation without adverse cardiac effects. Post-AF ablation high sinus HR was associated with a significantly lower clinical recurrence of AF after catheter ablation.
Предметные рубрики MeSH
AdultAgedAnti-Arrhythmia AgentsAtrial FibrillationCatheter AblationChi-Square DistributionDisease-Free SurvivalEchocardiographyElectrocardiography, AmbulatoryElectrophysiologic Techniques, CardiacFemaleHeart RateHumansKaplan-Meier EstimateLogistic ModelsMaleMiddle AgedMultivariate AnalysisOdds RatioPropensity ScoreRecurrenceRegistriesRisk FactorsTime FactorsTreatment OutcomeVagus Nerve