MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1158/1078-0432.ccr-05-2007

Медицинская библиотека · Clinical cancer research : an official journal of the American Association for Cancer Research · 2006

Bead-based ELISA for validation of ovarian cancer early detection markers.

Scholler Nathalie, Crawford Meghan, Sato Alicia, Drescher Charles W, O'Briant Kathy C, Kiviat Nancy, Anderson Garnet L, Urban Nicole

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: Efforts to validate ovarian cancer early detection biomarkers with immunoassays are challenged by the limited specimen volumes available. We sought to develop a specimen-efficient assay to measure CA125 in serum, assess its reproducibility, validity, and performance, and test its potential for multiplexing and combining with human epididymis protein 4 (HE4), a promising novel ovarian cancer marker.

EXPERIMENTAL

DESIGN

Four pairs of commercially available anti-CA125 antibodies and one pair of anti-HE4 antibodies were evaluated for accuracy in measuring known concentrations of antigen on a bead-based platform. The two best pairs were further assessed for reproducibility, validity, and the ability to discriminate between blinded serum samples obtained from ovarian cancer cases (n = 66) and women without ovarian cancer (n = 125).

RESULTS

Suitability for use in a bead-based assay varied across CA125 antibody pairs. Two CA125 bead-based assays were highly reproducible (overall correlations between replicates >/= 0.95; coefficients of variation < 0.2) and strongly correlated with the research standard CA125II RIA (correlations >/= 0.9). Their ability to distinguish ovarian cancer cases from non-cases based on receiver operating characteristic analyses (area under the curve, AUC, of 0.85 and 0.84) was close to that of the CA125II RIA (AUC, 0.87). The HE4 bead-based assay showed lower reproducibility but yielded an AUC of 0.89 in receiver operating characteristics analysis. Multiplexing was not possible but a composite marker including CA125 and HE4 achieved an AUC of 0.91.

CONCLUSION

Optimization procedures yielded two bead-based assays for CA125 that perform comparably to the standard CA125II RIA, which could be combined with an HE4 bead-based assay to improve diagnostic performance, and requires only 15 muL of sample each.

Для цитирования: Scholler Nathalie, Crawford Meghan, Sato Alicia, Drescher Charles W, O'Briant Kathy C, Kiviat Nancy, Anderson Garnet L, Urban Nicole. Bead-based ELISA for validation of ovarian cancer early detection markers.. Clinical cancer research : an official journal of the American Association for Cancer Research. 2006. DOI: 10.1158/1078-0432.ccr-05-2007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.