Development of a pregnancy-specific reference material for thyroid biomarkers, vitamin D, and nutritional trace elements in serum.

Boggs Ashley S P, Kilpatrick Lisa E, Burdette Carolyn Q, Tevis Denise S, Fultz Zachary A, Nelson Michael A, Jarrett Jeffery M, Kemp Jennifer V, Singh Ravinder J, Grebe Stefan K G, Wise Stephen A, Kassim Brittany L, Long Stephen E

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

OBJECTIVES

Matrix differences among serum samples from non-pregnant and pregnant patients could bias measurements. Standard Reference Material 1949, Frozen Human Prenatal Serum, was developed to provide a quality assurance material for the measurement of hormones and nutritional elements throughout pregnancy.

METHODS

Serum from non-pregnant women and women in each trimester were bottled into four levels based on pregnancy status and trimester. Liquid chromatography tandem mass spectrometry (LC-MS/MS) methods were developed and applied to the measurement of thyroid hormones, vitamin D metabolites, and vitamin D-binding protein (VDBP). Copper, selenium, and zinc measurements were conducted by inductively coupled plasma dynamic reaction cell MS. Thyroid stimulating hormone (TSH), thyroglobulin (Tg), and thyroglobulin antibody concentrations were analyzed using immunoassays and LC-MS/MS (Tg only).

RESULTS

Certified values for thyroxine and triiodothyronine, reference values for vitamin D metabolites, VDBP, selenium, copper, and zinc, and information values for reverse triiodothyronine, TSH, Tg, and Tg antibodies were assigned. Significant differences in serum concentrations were evident for all analytes across the four levels (p≤0.003). TSH measurements were significantly different (p<0.0001) among research-only immunoassays. Tg concentrations were elevated in research-only immunoassays vs. Federal Drug Administration-approved automated immunoassay and LC-MS/MS. Presence of Tg antibodies increased differences between automated immunoassay and LC-MS/MS.

CONCLUSIONS

The analyte concentrations' changes consistent with the literature and the demonstration of matrix interferences in immunoassay Tg measurements indicate the functionality of this material by providing a relevant matrix-matched reference material for the different stages of pregnancy.

Для цитирования: Boggs Ashley S P, Kilpatrick Lisa E, Burdette Carolyn Q, Tevis Denise S, Fultz Zachary A, Nelson Michael A, Jarrett Jeffery M, Kemp Jennifer V, Singh Ravinder J, Grebe Stefan K G, Wise Stephen A, Kassim Brittany L, Long Stephen E. Development of a pregnancy-specific reference material for thyroid biomarkers, vitamin D, and nutritional trace elements in serum.. Clinical chemistry and laboratory medicine. 2020. DOI: 10.1515/cclm-2020-0977.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.