Tuboimpedance: A New Test of Eustachian Tube Function.

Smith Matthew E, Zou Charlie C, Blythe Andrew J C, Tysome James R

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Objective Eustachian tube (ET) dysfunction is most frequently caused by a failure of the ET to adequately open; however, there is currently no reliable method of assessing this. Tubomanometry has recently shown good interindividual repeatability as a measure of ET function by measuring middle ear pressure after the application of regulated nasopharyngeal pressures during swallowing. We present the first reports of a novel test: middle ear impedance measurements during standard nasopharyngeal pressure application (tuboimpedance). We assess repeatability in healthy ears and any advantages over tubomanometry. Study Design Exploratory cohort diagnosis study. Setting Tertiary referral center. Subjects Twenty screened, healthy ears (10 volunteers). Methods Tubomanometry and tuboimpedance tests were performed while individuals swallowed with applied nasopharyngeal pressures of 20, 30, 40, and 50 mbar. Eustachian tube opening detection rate and test repeatability (measured by intraclass correlation coefficient [ICC]) for immediate and delayed repeats at each pressure were compared. Results ET opening was detected more frequently using tuboimpedance, with a 100% detection rate using a nasopharyngeal pressure of 30 mbar or more, compared to 88% to 96% with tubomanometry. Detection of ET opening at 20 mbar was possible with tuboimpedance. Repeatability of both tests was mostly strong (ICC >0.7) for both immediate and delayed repeats. Repeatability for the tubomanometry R value was only fair to moderate. Conclusion Tuboimpedance may provide a repeatable measure of ET opening that is easier to perform due to lower nasopharyngeal pressures required and fewer issues with poor ear-probe sealing. Further assessment in patients with different forms of ET dysfunction is required.

Для цитирования: Smith Matthew E, Zou Charlie C, Blythe Andrew J C, Tysome James R. Tuboimpedance: A New Test of Eustachian Tube Function.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2017. DOI: 10.1177/0194599816686546.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.