Cureus · 2023
Comparative Evaluation of Dentinal Defects After Root Canal Preparation Using Various Nickel Titanium Files: An In Vitro Study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Batra Renu, Dixit Ankita, Tiwari Anushree, Kumar Amit, Sinha Shagun, Badnaware Sheetal, Singh Ramanpal
Аннотация
AIM: This study set out to compare the damage done to dentin by three distinct titanium file brands - the Hyflex EDM, the ProTaper Next, and the Waveone Gold Nickel - in order to draw conclusions about which one is the most effective.
MATERIALS AND METHODS: Forty-first premolars in the mandible with straight canals and single roots were instrumented using Hyflex EDM, Waveone Gold, and Protaper Next. Dentinal flaws after endodontic treatment were studied by sectioning specimens using a hard tissue microtome and analyzing them under a stereomicroscope.
RESULTS: There was no discernible variation between the groups in the coronal third (p=0.312) or apical third (p=0.076). Hyflex EDM and Protaper Next differed significantly in the middle portion of the tape (p=0.016). The Hyflex EDM sample had the fewest cracks. There was no statistically significant difference between Hyflex EDM and Waveone Gold; however, Hyflex EDM had fewer fractures in the middle third of the sample than Waveone Gold did.
CONCLUSION: Electric discharge machining (EDM) files made from Hyflex proved to be far superior to their Protaper Next and Waveone Gold counterparts as they induced the fewest cracks in the middle third of the root dentin.
MATERIALS AND METHODS: Forty-first premolars in the mandible with straight canals and single roots were instrumented using Hyflex EDM, Waveone Gold, and Protaper Next. Dentinal flaws after endodontic treatment were studied by sectioning specimens using a hard tissue microtome and analyzing them under a stereomicroscope.
RESULTS: There was no discernible variation between the groups in the coronal third (p=0.312) or apical third (p=0.076). Hyflex EDM and Protaper Next differed significantly in the middle portion of the tape (p=0.016). The Hyflex EDM sample had the fewest cracks. There was no statistically significant difference between Hyflex EDM and Waveone Gold; however, Hyflex EDM had fewer fractures in the middle third of the sample than Waveone Gold did.
CONCLUSION: Electric discharge machining (EDM) files made from Hyflex proved to be far superior to their Protaper Next and Waveone Gold counterparts as they induced the fewest cracks in the middle third of the root dentin.