MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5395/rde.2023.48.e16

Медицинская библиотека · Restorative dentistry & endodontics · 2023

Influence of CBCT parameters on image quality and the diagnosis of vertical root fractures in teeth with metallic posts: an ex vivo study.

Lagos de Melo Larissa Pereira, Queiroz Polyane Mazucatto, Moreira-Souza Larissa, Nadaes Mariana Rocha, Santaella Gustavo Machado, Oliveira Matheus Lima, Freitas Deborah Queiroz

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to evaluate the influence of peak kilovoltage (kVp) and a metal artifact reduction (MAR) tool on image quality and the diagnosis of vertical root fracture (VRF) in cone-beam computed tomography (CBCT).

MATERIALS AND

METHODS

Twenty single-rooted human teeth filled with an intracanal metal post were divided into 2 groups: control (n = 10) and VRF (n = 10). Each tooth was placed into the socket of a dry mandible, and CBCT scans were acquired using a Picasso Trio varying the kVp (70, 80, 90, or 99), and the use of MAR (with or without). The examinations were assessed by 5 examiners for the diagnosis of VRF using a 5-point scale. A subjective evaluation of the expression of artifacts was done by comparing random axial images of the studied protocols. The results of the diagnoses were analyzed using 2-way analysis of variance and the Tukey post hoc test, the subjective evaluations were compared using the Friedman test, and intra-examiner reproducibility was evaluated using the weighted kappa test (α = 5%).

RESULTS

The kVp and MAR did not influence the diagnosis of VRF (p > 0.05). According to the subjective classification, the 99 kVp protocol with MAR demonstrated the least expression of artifacts, while the 70 kVp protocol without MAR led to the most artifacts.

CONCLUSIONS

Protocols with higher kVp combined with MAR improved the image quality of CBCT examinations. However, those factors did not lead to an improvement in the diagnosis of VRF.

Для цитирования: Lagos de Melo Larissa Pereira, Queiroz Polyane Mazucatto, Moreira-Souza Larissa, Nadaes Mariana Rocha, Santaella Gustavo Machado, Oliveira Matheus Lima, Freitas Deborah Queiroz. Influence of CBCT parameters on image quality and the diagnosis of vertical root fractures in teeth with metallic posts: an ex vivo study.. Restorative dentistry & endodontics. 2023. DOI: 10.5395/rde.2023.48.e16.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.