A fully digital workflow to register maxillomandibular relation using a jaw motion tracer for fixed prosthetic rehabilitation: A technical report.
Аннотация
OBJECTIVE
This technique aimed to describe a fully digital workflow to register maxillomandibular relation for fixed prosthetic rehabilitation.
CLINICAL CONSIDERATIONS: Mandibular kinematics could be reproduced in a four-dimensional (4D) virtual patient based on the intraoral scan, facial scan, cone beam computed tomography, and jaw motion trajectory, which helped record centric relation and determine a proper occlusal vertical dimension in a virtual environment. The therapeutic position could be exported directly to the dental computer-aided design software for digital waxing design with a facial scan. The 4D virtual patient was also used to verify the functional and esthetic outcomes of provisional restorations.
CONCLUSIONS
This novel approach digitized the process of determination, delivery, and double-check of maxillomandibular relation, thus contributing to the establishment of a completely digital workflow for fixed prosthetic rehabilitation.
CLINICAL SIGNIFICANCE: Registration of maxillomandibular relation, including centric relation and occlusal vertical dimension is critical to the success of prosthetic rehabilitation. Traditional procedures are complex and time-consuming, and heavily rely on the clinical experience of dentists. A fully digital approach to creating a 4D virtual patient and registering the maxillomandibular relation is established, which guides to determine a proper occlusal vertical dimension in centric relation. Digital delivery and double-check can simplify the conventional procedure and ensure that the determined maxillomandibular relation is reliable.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.