DOI 10.1007/s00115-021-01217-7

Медицинская библиотека · Der Nervenarzt · 2021

[Inferior temporal electrodes in 24-h EEG].

Kleine Bert-Ulrich, Miosge Ragna-Jill, Krümmer Norma, Krause Thomas, Weise Gesa, Berrouschot Jörg

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To improve the sensitivity of the EEG in the diagnosis and classification of seizures or epilepsy, long-term recording with inferior temporal electrodes are recommended.

MATERIAL AND

METHODS

The spatial distribution of epileptiform discharges from 24‑h EEG with 25 electrodes (10-20, extended by F9/F10, T9/T10, P9/P10) was retrospectively analyzed in 25 cases.

RESULTS

Maximum negativity was located below the 10-20 electrodes in 84%. Epileptiform discharges were more clearly detected on inferior temporal electrodes in 64%. In the intention-to-test population of 77 patients the number needed to test with extra electrodes was estimated as 5.

CONCLUSION

Recording EEG with 25 electrodes for 24 h improves the detection and localization of temporal epileptiform discharges also in geriatric patients with suspected nonlesional epilepsy.

Для цитирования: Kleine Bert-Ulrich, Miosge Ragna-Jill, Krümmer Norma, Krause Thomas, Weise Gesa, Berrouschot Jörg. [Inferior temporal electrodes in 24-h EEG].. Der Nervenarzt. 2021. DOI: 10.1007/s00115-021-01217-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.