Stress-shielding resistant design of custom pelvic prostheses using lattice-based topology optimization.

Babazadeh-Naseri Ata, Li Geng, Shourijeh Mohammad S, Akin John E, Higgs Iii C Fred, Fregly Benjamin J, Dunbar Nicholas J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Endoprosthetic reconstruction of the pelvic bone using 3D-printed, custom-made implants has delivered early load-bearing ability and good functional outcomes in the short term to individuals with pelvic sarcoma. However, excessive stress-shielding and subsequent resorption of peri‑prosthetic bone can imperil the long-term stability of such implants. To evaluate the stress-shielding performance of pelvic prostheses, we developed a sequential modeling scheme using subject-specific finite element models of the pelvic bone-implant complex and personalized neuromusculoskeletal models for pre- and post-surgery walking. A new topology optimization approach is introduced for the stress-shielding resistant (SSR) design of custom pelvic prostheses, which uses 3D-printable porous lattice structures. The SSR optimization was applied to a typical pelvic prosthesis to reconstruct a type II+III bone resection. The stress-shielding performance of the optimized implant based on the SSR approach was compared against the conventional optimization. The volume of the peri‑prosthetic bone predicted to undergo resorption post-surgery decreased from 44 to 18%. This improvement in stress-shielding resistance was achieved without compromising the structural integrity of the prosthesis. The SSR design approach has the potential to improve the long-term stability of custom-made pelvic prostheses.

Для цитирования: Babazadeh-Naseri Ata, Li Geng, Shourijeh Mohammad S, Akin John E, Higgs Iii C Fred, Fregly Benjamin J, Dunbar Nicholas J. Stress-shielding resistant design of custom pelvic prostheses using lattice-based topology optimization.. Medical engineering & physics. 2023. DOI: 10.1016/j.medengphy.2023.104012.

Предметные рубрики MeSH